PKU5315EPI Ericsson Power Modules, PKU5315EPI Datasheet - Page 4

DC/DC Converters & Regulators 34W 15V OUT 2.25A 33.02x22.86x7.50 mm

PKU5315EPI

Manufacturer Part Number
PKU5315EPI
Description
DC/DC Converters & Regulators 34W 15V OUT 2.25A 33.02x22.86x7.50 mm
Manufacturer
Ericsson Power Modules
Series
PKU-Er
Datasheet

Specifications of PKU5315EPI

Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PKU5315EPI
Manufacturer:
MURATAPS
Quantity:
12 000
Part Number:
PKU5315EPI
Manufacturer:
ERICSSON/爱立信
Quantity:
20 000
E
Absolute Maximum Ratings
Stress in excess of Absolute Maximum Ratings may cause permanent damage. Absolute Maximum Ratings, sometimes referred to as no destruction limits, are
normally tested with one parameter at a time exceeding the limits of Output data or Electrical Characteristics. If exposed to stress above these limits, function and
performance may degrade in an unspecified manner.
Fundamental Circuit Diagram
Characteristics
T
T
V
V
V
V
V
Prepared (also subject responsible if other)
MICMALE
Approved
EAB/FJB/GMF (Natalie Johansson)
PKU 5000E series
DC/DC converters, Input 18-72 V, Output up to 10 A/35 W
P1
S
I
iso
tr
RC
adj
Operating Temperature (see Thermal Consideration section)
Storage temperature
Input voltage
Isolation voltage (input to output test voltage)
Input voltage transient (t
Remote Control pin voltage
(see Operating Information section)
Adjust pin voltage (see Operating Information section)
RC
+IN
-IN
p
100 ms)
PWM and primary
side gate driver
Bias supply
Checked
See § 1
Positive logic option
Negative logic option
Ericsson Internal
PRODUCT SPECIFICATION
No.
2/1301-BMR 660 00+ Uen
Date
2009-04-07
Gate drive
secondary side
Technical Specification
Voltage
monitoring
EN/LZT 146 391 R4B May 2009
© Ericsson AB
Rev
D
min
-0.5
-0.5
-0.5
-0.5
-40
-55
Reference
typ
+105
+100
1500
2xV
max
+80
100
+OUT
40
40
-OUT
oi
Vadj
1 (14)
Unit
Vdc
°C
°C
V
V
V
V
V
4