DC/DC Converters & Regulators 20W 48V/+-15V+-670mA

BWR-15/670-D48A

Manufacturer Part Number
BWR-15/670-D48A
Description
DC/DC Converters & Regulators 20W 48V/+-15V+-670mA
Manufacturer
Murata Power Solutions Inc
Series
BWRr
Datasheet

Specifications of BWR-15/670-D48A

Product
Isolated
Output Power
10 W
Input Voltage Range
18 V to 75 V
Input Voltage (nominal)
48 V
Number Of Outputs
2
Output Voltage (channel 1)
+/- 15 V
Output Current (channel 1)
+/- 670 mA
Output Voltage (channel 2)
15 V
Output Current (channel 2)
+/- 670 mA
Isolation Voltage
1.5 KV
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
BWR-15/670-D48A
Manufacturer:
DATEL
Quantity:
452
Performance/Functional Specifications
Typical @ T
internally upon request. Contact MPS Applications Engineering for details.
Input Voltage Range:
Input Current
Input Filter Type
Overvoltage Shutdown:
Reverse-Polarity Protection
On/Off (Sync.) Control (Pin 4)
V
Temperature Coefficient
Ripple/Noise (20MHz BW)
Line/Load Regulation
Efficiency
Isolation Voltage
Isolation Capacitance
Current Limiting
Overvoltage Protection
Transient Response (50% load step)
Switching Frequency
Operating Temperature (ambient):
Storage Temperature
Flammability
Dimensions
Shielding
Case Connection:
Case Material
Pin Material
Weight
OUT
D5A Models
D12A Models
D48A Models
D5A Models
D12A Models
D48A Models
±5V Outputs
±9/12/15V Outputs
Without Derating
With Derating
D5A and D12A Models
D48A Models
These converters require a minimum 20% loading on each output to maintain specified
regulation. Operation under no-load conditions will not damage these devices; however
they may not meet all listed specifications.
Application-specific internal input/output filtering can be recommended and perhaps added
Applying a voltage to the Control pin when no input power is applied to the converter can
cause permanent damage to the converter.
"D48A" models have BASIC, "D5A" and "D12A" models have Functional insulation.
Devices can be screened or modified for higher guaranteed isolation voltages.
Contact MPS Applications Engineering for details.
Accuracy (50% load):
A
= +25°C under nominal line voltage and full-load conditions, unless noted.
Dynamic Characteristics
Environmental
Physical
Output
Input
4.7-7.5 Volts (5V nominal)
9-36 Volts (24V nominal)
18-75 Volts (48V nominal)
See Ordering Guide
Pi
10 Volts
40 Volts
80 Volts
Yes (Instantaneous, 10A maximum)
TTL high = off, low (or open) = on
±1.5%, maximum
±1%, maximum
±0.02% per °C
See Ordering Guide
See Ordering Guide
See Ordering Guide
1500Vdc, minimum
550pF
Auto-recovery
Zener/transorb clamps, magnetic feedback
200μsec max. to ±1.5% of final value
165kHz (±15kHz)
–40 to +50/55/60°C (Model dependent)
to +100°C (See Derating Curves)
–40 to +105°C
UL 94V-0
2" x 2" x 0.45" (51 x 51 x 11.4mm)
5-sided
Pin 2 (–V
Pin 1 (+V
Corrosion resistant steel with
non-conductive, epoxy-based, black
enamel finish and plastic baseplate
Gold-plated copper alloy
2.7 ounces (75.6 grams)
IN
IN
www.murata-ps.com
)
)
Floating Outputs
Since these are isolated DC/DC converters, their outputs are "floating." Any
BWR model may be configured to produce an output of 10V, 24V or 30V
(for
the +Output and –Output pins (pins 5 and 7), with either output grounded.
The Common pin (pin 6) should be left open. Minimum 20% loading is
recommended under these conditions. The total output voltage span may be
externally trimmed as described below.
Filtering and Noise Reduction
All A-Series BWR 15-20 Watt DC/DC Converters achieve their rated ripple
and noise specifications without the use of external input/output capacitors.
In critical applications, input/output ripple and noise may be further reduced
by installing electrolytic capacitors across the input terminals and/or low-ESR
tantalum or electrolytic capacitors across the output terminals. Output capac-
itors should be connected between their respective output pin (pin 5 or 7) and
Common (pin 6) as shown in Figure 2. The caps should be located as close
to the power converters as possible. Typical values are listed in the tables
below. In many applications, using values greater than those listed will yield
better results.
T E C H N I C A L N O T E S
These are stress ratings. Exposure of devices to greater than any of these conditions may
adversely affect long-term reliability. Proper operation under conditions other than those
listed in the Performance/Functional Specifications Table is not implied.
Input Voltage:
Input Reverse-Polarity Protection
Output Overvoltage Protection
Output Current
Storage Temperature
Lead Temperature
±
To Reduce Input Ripple
To Reduce Output Ripple
1 5 - 2 0 W , D u a l O u t p u t D C / D C C o n v e r t e r s
5V,
D5A Models
D12A Models
D48A Models
±5V Outputs
±12V Outputs
±15V Outputs
±
D5A Models
D12A Models
D48A Models
±5V Outputs
±9/12/15V Outputs
12V or
±
15V models, respectively) by applying the load across
Technical enquiries email: sales@murata-ps.com, tel:
Absolute Maximum Ratings
47μF, 16V
20μF, 50V
20μF, 100V
47μF, 10V, Low ESR
22μF, 20V, Low ESR
12 Volts
44 Volts
88 Volts
Current must be <10A. Brief
duration only. Fusing recommended.
6.8 Volts, limited duration
15 Volts, limited duration
18 Volts, limited duration
Current limited. Max. current and
–40 to +105°C
See soldering guidelines
BWR Models
MDC_BWR15_20_B02 Page 3 of 6
short-circuit duration are model
dependent.
+1 508 339 3000