EWR1601-0G POWER ONE, EWR1601-0G Datasheet - Page 19

DC/DC Converters & Regulators

EWR1601-0G

Manufacturer Part Number
EWR1601-0G
Description
DC/DC Converters & Regulators
Manufacturer
POWER ONE
Datasheet

Specifications of EWR1601-0G

Output Power
120 W
Input Voltage Range
66 V to 150 V
Input Voltage (nominal)
110 V
Number Of Outputs
1
Output Voltage (channel 1)
24.7 V
Output Current (channel 1)
5 A
Package / Case Size
103 mm x 114 mm x 138 mm
Output Type
Regulated
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
BCD20020-G Rev AB1, 17-Nov-09
Fig. 19
Cage clamp terminals. Use 0.5 to 2.5 mm
solid or stranded wires depending on local requirements.
This fuse is designed to break an overcurrent in case of a
malfunction of the converter and is not customer-accessible.
External fuses in the wiring to one or both input lines (L and/
or N ) may be necessary to ensure compliance with local
requirements. A built-in second fuse in the neutral path is
available as option F.
A second fuse in the wiring to the neutral terminal N or option
F is needed if:
Models with Option F: Caution! Double-pole/neutral fusing.
If the converters operate at source voltages above 250 VDC,
an external fuse or a circuit breaker at system level should be
installed.
Protection Degree
The protection degree of the converters is IP 20. Protective
covers over input and output terminals are available on
request; see Accessories.
Cleaning Agents
Any penetration of liquid or foreign solid objects is to be
prevented, since the converters are not hermetically sealed.
• Local requirements demand an individual fuse in each
• Neutral and earth impedance is high or undefined
• Phase and neutral of the mains are not defined or cannot be
Caution:
• Installation must strictly follow the national safety regulations.
• Do not open this apparatus!
source line
assigned to the corresponding terminals (L
N to neutral).
®
1
2
3
2
(AWG 20 to 12)
10074
125, 250 Watt AC-DC and DC-DC DIN-Rail Converters
to phase and
Page 19 of 25
Standards and Approvals
The converters of the LW Series with feature E were approved
according to IEC/EN 60950-1:2001 (IEC/EN 60950 for models
without E), IEC 61010-1:C11:2002 (models without E: IEC
61010-1), and EN 50178:1997 (with and without E).
The converters are UL508-listed and approved according to
UL 60950-1 and CAN/CSA C22.2 No. 60950-1.
Safety approvals for EW models are in process.
The converters have been designed in accordance with said
standards for:
The converters are subject to manufacturing surveillance in
accordance with the above mentioned UL standards and with
ISO9001:2000.
Railway Applications
The W Series converters have been designed observing the
railway standards EN 50155 and EN 50121. All boards are
coated with a protective lacquer.
The EW Series is particularily suitable for connection to 110 V
railway batteries.
• Class I equipment
• Power supply for building-in, vertical mounting on 35 mm
• Overvoltage category II (III for 110 VAC supply)
• Basic insulation between input and case, based on
• Double or reinforced insulation between input and output,
• Functional insulation between outputs and case.
• Functional insulation between outputs.
• Pollution degree 3 environment (AC-input) and degree 2
DIN-rail or on a wall
250 VAC
based on 250 VAC and 350 VDC.
(DC input).