BMP-15/1.3-D48 Murata Power Solutions Inc, BMP-15/1.3-D48 Datasheet
BMP-15/1.3-D48
Specifications of BMP-15/1.3-D48
Related parts for BMP-15/1.3-D48
BMP-15/1.3-D48 Summary of contents
Page 1
... Applicable to a wide range of telecom, computer and other OEM applications, BMP Model DC/DC’s offer ±5V, ±12V and ±15V outputs. They operate from four different input voltage ranges with total available output being a function of the selected range. "Q12" models operate from 10-36V and deliver 25W. "Q48" models operate from 18-75V and deliver 30W. For " ...
Page 2
... BMP-15/1.3-D24 ±15 ±1.3 BMP-15/1.3-Q48 ±15 ±1.3 BMP-15/1.3-D48 ±15 ±1.3 ➀ Typical +25°C under nominal line voltage and balanced "full-load" conditions unless otherwise noted. A For BMP devices, "full load" function of each device's input voltage range. See Output Power Considerations and Technical Notes for more details. ...
Page 3
... TOP VIEW 0.120 DIA. (3.048) (4 PLACES) 0.10 (2.54) MATERIAL: BLACK ANODIZED ALUMINUM 4 MOUNTING SCREWS AND 0.009 (0.229) THERMAL PAD INCLUDED Third Angle Projection Technical enquiries email: sales@murata-ps.com, tel: MDC_BMP25-40W.B03 Page 0.40 (10.16) 2.00 1.200 (30.48) (50.80) 0.50 (12.70) +1 508 339 3000 ...
Page 4
... Proper operation under conditions other than those listed in the Performance/Functional Specifi cations Table is not implied Floating Outputs Since these are isolated DC/DC converters, their outputs are "fl oating." Any BMP model may be confi gured to produce an output of 10V, 24V or 30V (for 5V, 12V or ± ± ...
Page 5
... Ambient Temperature (°C) Figure 3b. Temperature Derating With Heat Sink Natural Convection Cooling 150 Linear Feet Per Minute 300 Linear Feet Per Minute Ambient Temperature (°C) Figure 4b. Temperature Derating With Heat Sink Technical enquiries email: sales@murata-ps.com, tel: MDC_BMP25-40W.B03 Page 508 339 3000 ...
Page 6
... Watts, respectively. Observing these power limitations is the user's responsibility. As indicated by its Part Number Structure, each ±5V, ±12V or ±15V BMP device is capable of sourcing up to ±4, ±1.65 or ±1.3 Amps, respectively. Users have the fl exibility of loading either output up to these limits; however you must be extremely careful not to exceed the total output power rating of any given device. If, for example, a ± ...
Page 7
... BMP-5/4-Q12 BMP-5/4-Q48 BMP-5/4-D24 BMP-5/4-D48 BMP-12/1.65-Q12 BMP-12/1.65-Q48 BMP-12/1.65-D24 BMP-12/1.65-D48 BMP-15/1.3-Q12 BMP-15/1.3-Q48 BMP-15/1.3-D24 BMP-15/1.3-D48 3 +INPUT 5 ON/OFF CONTROL 2 –INPUT Figure 6. Driving the On/Off Control Pin Murata Power Solutions, Inc. 11 Cabot Boulevard, Mansfi eld, MA 02048-1151 U.S.A. Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356 www ...