HBAA-40-W-AG POWER ONE, HBAA-40-W-AG Datasheet - Page 5

no-image

HBAA-40-W-AG

Manufacturer Part Number
HBAA-40-W-AG
Description
Linear & Switching Power Supplies 5/+12/-12V, 2/.4/.4A
Manufacturer
POWER ONE
Datasheet

Specifications of HBAA-40-W-AG

Product
Linear
Commercial/medical
Commercial
Output Power Rating
15 W
Input Voltage
100 VAC to 264 VAC
Number Of Outputs
3
Output Voltage (channel 1)
5 V
Output Current (channel 1)
3 A
Output Voltage (channel 2)
12 V
Output Current (channel 2)
1 A
Output Voltage (channel 3)
- 5 V
Output Current (channel 3)
0.4 A
Mounting Style
Chassis
Output Type
Isolated
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Input Specifications
PARAMETER
Input Voltage - AC
Input Frequency
Line Regulation
NOTES:
Output Specifications
PARAMETER
Output Adjustment
Efficiency
Ripple and Noise
Load Regulation
Transient Response
NOTES:
Safety, Regulatory, and EMI Specifications
PARAMETER
Agency Approvals
Dielectric Withstand
Voltage
Electromagnetic
Interference
Leakage Current
Interface Signals and Internal Protection
PARAMETER
Overvoltage Protection
Remote Sense
Overcurrent/Short Circuit
Protection
Master/Slave Operation
MCD10016 Rev. 1.2, 13-Nov-09
(Note 1, 2)
(Note 2)
1) Derate output current 10% for 50Hz operation.
2) Input voltage tolerance for 230VAC operation is +15%, -10%.
1) OUTPUT VOLTAGE ADJUSTMENTS:
2) Full load, 20MHz bandwidth.
potentiometer on the power supply PCB and use a screwdriver to adjust the output pot. The HAD12 and HAD15 3 terminal regulator outputs are not
adjustable.
CONDITIONS/DESCRIPTION
Jumper selectable, shipped factory configured for
120VAC operation. All models must be externally
fused for proper operation. Fuse ratings are marked
on each unit. Consult factory for each unit’s fuse
requirements.
AC input.
Output voltage charge for a 10% line change: F case models.
HAD12, HAD15.
Outputs with adjustable three terminal regulators.
All other models.
CONDITIONS/DESCRIPTION
Minimum output adjustment range (Note 1).
5 volt outputs.
12 volt and 15 volt outputs.
24 volt and higher outputs.
F case models.
5 volt, 12 volt, and 15 volt models.
All three terminal regulator outputs.
24 volt through 250 volt models.
Output change for a 50% load change: F case models.
HAD12, HAD15.
Outputs with adjustable three terminal regulators.
All other models.
Recovery time, to within 1% of initial set point due to a 50% load change.
CONDITIONS/DESCRIPTION
UL60950-1.
CSA 60950-1 “cUL”.
EN60950-1.
IEC60950-1.
Input to output.
Input to ground.
FCC CFR title 47 Part 15 Sub-Part B - conducted.
EN55022 / CISPR 22 conducted.
EN55022 / CISPR 22 radiated.
Per EN60950
CONDITIONS/DESCRIPTION
Provided on 5 volt output units where indicated.
Other outputs may use optional overvoltage protectors OVP-12 and OVP-24.
Total voltage compensation for cable losses with respect to the main output.
Provided on models where indicated.
Automatic current limit/foldback. Rated as a percentage of output power.
For parallel operation of up to 6 units. Master/slave pin provided on F case models only. Contact factory for application notes.
Output voltage adjustments can be made to within ±5% of factory setting of nominal output voltage. Locate the “Vadj”
Page 5 of 9
(264VAC)
Linear Power Supplies Data Sheet
100 VAC Tap
120 VAC Tap
220 VAC Tap
240 VAC Tap
3.0mV
Compatible with system compliance to Level B.
PK-PK
-0.01
-0.05
-0.02
-0.05
3000
1500
-1.0
-0.5
-0.5
MIN
104
191
209
MIN
115
MIN
MIN
5.8
87
47
-5
-1
plus 0.02% of output voltage, max
NOM
NOM
100
120
220
240
NOM
NOM
120
45
55
60
23
Approved
www.power-one.com
+0.01
+0.05
+0.02
+0.05
+1.0
+0.5
+0.5
MAX
MAX
110
132
242
264
MAX
MAX
250
140
3.0
5.0
0.2
6.6
63
+5
+1
50
50
mV
mV
%
UNITS
UNITS
UNITS
UNITS
VAC
VAC
PK-PK
mV
Hz
μA
%
%
%
PK-PK
PK-PK
%
μ
%
V
s