AD-55A Mean Well, AD-55A Datasheet

Linear & Switching Power Supplies 51.38W 13.8V 3.5A, 13.4V 0.23A

AD-55A

Manufacturer Part Number
AD-55A
Description
Linear & Switching Power Supplies 51.38W 13.8V 3.5A, 13.4V 0.23A
Manufacturer
Mean Well
Datasheet

Specifications of AD-55A

Product
Switching
Commercial/medical
Commercial
Output Power Rating
48 W
Input Voltage
88 VAC to 264 VAC, 124 VDC to 370 VDC
Number Of Outputs
2
Output Voltage (channel 1)
13.8 V
Output Current (channel 1)
3.5 A
Output Voltage (channel 2)
13.4 V
Output Current (channel 2)
0.23 A
Mounting Style
Chassis
Output Type
DC
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AD-55AAL
Manufacturer:
SUMMIT
Quantity:
760
SPECIFICATION
MODEL
OUTPUT
INPUT
PROTECTION
FUNCTION
ENVIRONMENT
SAFETY &
EMC
(Note 4)
OTHERS
NOTE
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVERLOAD
OVER VOLTAGE
BATTERY LOW
DC ALARM SIGNAL(OPTIONAL)
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
HARMONIC CURRENT
EMS IMMUNITY
MTBF
DIMENSION
PACKING
OUTPUT NUMBER
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
RIPPLE & NOISE (max.)
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
EMI CONDUCTION & RADIATION
55W Single Output with Battery Charger(UPS Function)
Note.3
Note.2
AD-55A
CH1
13.8V
3.5A
0 ~ 4A
51.38W
100mVp-p
CH1: 12 ~ 14.5V
800ms, 50ms/230VAC
80ms/230VAC
88 ~ 264VAC
47 ~ 63Hz
1.6A/115VAC
105 ~ 150% rated output power
Protection type : AC Charging Mode : Hiccup mode, recovers automatically after fault condition is removed
CH1:15.87 ~ 18.63V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
9.5 ~ 11V
AC fail CN1 PIN2
Battery low under charge voltage 82.5% 2% CN1 PIN1
Normal 0.8V max. Abnormal 5V 0.5V
-10 ~ +60
20 ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
I/P-O/P:3KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A
304.3K hrs min.
159*97*38mm (L*W*H)
0.5Kg; 24pcs/12.6Kg/0.75CUFT
71%
COLD START 20A/115VAC
<1mA / 240VAC
1.0%
0.5%
0.5%
0.03%/
(0~50 ) on CH1 output
(Refer to output load derating curve)
UPS Mode : Protected by internal fuse
I/P-FG:1.5KVAC
124 ~ 370VDC
1A/230VAC
MIL-HDBK-217F (25 )
16ms/115VAC at full load
1600ms, 50ms/115VAC at full load
CH2
13.4V
0.23A
--------
--------
--------
--------
--------
40A/230VAC
O/P-FG:0.5KVAC
AD-55B
CH1
27.6V
1.8A
0 ~ 2A
53.92W
100mVp-p
CH1: 24 ~ 29V
20 ~ 22V
74%
CH1:31.74 ~ 37.26V
1.0%
0.5%
0.5%
A D - 5 5
CH2
26.5V
0.16A
--------
--------
--------
--------
--------
File Name:AD-55-SPEC 2010-11-29
s e r i e s

Related parts for AD-55A

AD-55A Summary of contents

Page 1

... Single Output with Battery Charger(UPS Function) SPECIFICATION MODEL AD-55A OUTPUT NUMBER CH1 DC VOLTAGE 13.8V RATED CURRENT 3.5A CURRENT RANGE RATED POWER 51.38W RIPPLE & NOISE (max.) 100mVp-p Note.2 OUTPUT VOLTAGE ADJ. RANGE CH1 14.5V VOLTAGE TOLERANCE Note.3 LINE REGULATION LOAD REGULATION ...