HRPG-300-15 Mean Well, HRPG-300-15 Datasheet
HRPG-300-15
Specifications of HRPG-300-15
Related parts for HRPG-300-15
HRPG-300-15 Summary of contents
Page 1
... HARMONIC CURRENT Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11, ENV50204, EN55024, EN61000-6-2, heavy industry level, criteria A EMS IMMUNITY MTBF 176K hrs min. OTHERS DIMENSION 199*105*41mm (L*W*H) PACKING 0.95Kg;15pcs/15.3Kg/0.69CUFT NOTE HRPG-300-7.5 HRPG-300-12 HRPG-300-15 HRPG-300-24 HRPG-300-36 HRPG-300-48 5V 7.5V 12V 60A 40A 27A 0 ~ 60A 0 ~ 40A 0 ~ 27A 300W 300W ...
Page 2
... L=5 FAN 167.5 167.5 RECTIFIERS & FILTER RECTIFIERS & FILTER DETECTION CIRCUIT O.V.P. REMOTE CONTROL 85 100 125 135 155 INPUT VOLTAGE (V) 60Hz File Name:HRPG-300-SPEC 2010-11- Unit:mm 12.25 Air flow direction 12.25 12.25 fosc : 70KHz AUX AUXG + DC-OK RC+ RC 264 ...
Page 3
... DC-OK signal is a TTL level signal. High when PSU turns on. Between DC-OK(pin6) and GND(pin4) Output Status 3 OFF CN100 Sense lines should +S -S LOAD be twisted in pairs (Pin7) (Pin8 CN100 CN100 1 AUX DC-OK GND +S 2 AUXG RC- RC+ -S Fig 1.1 CN100 AUX DC-OK GND + AUXG RC- RC+ -S Fig 2.1 File Name:HRPG-300-SPEC 2010-11- ...
Page 4
... Single Output with PFC Function 3.Remote Control The PSU can be turned ON/OFF by using the "Remote ON/OFF" function Between RC+(pin3) and RC-(pin5) Output Status SW ON (Short) OFF SW OFF (Open CN100 Fig 3 CN100 1 AUX DC-OK GND + AUXG RC- RC File Name:HRPG-300-SPEC 2010-11-29 ...