Linear & Switching Power Supplies 336W 48V 7A W/ PFC FUNCTION

HRP-300-48

Manufacturer Part Number
HRP-300-48
Description
Linear & Switching Power Supplies 336W 48V 7A W/ PFC FUNCTION
Manufacturer
Mean Well
Datasheet

Specifications of HRP-300-48

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
SPECIFICATION
MODEL
OUTPUT
INPUT
PROTECTION
FUNCTION
ENVIRONMENT
SAFETY &
EMC
(Note 4)
OTHERS
NOTE
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVERLOAD
OVER VOLTAGE
OVER TEMPERATURE
DC OK SIGNAL
FAN CONTROL (Typ.)
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
EMS IMMUNITY
MTBF
DIMENSION
PACKING
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
RIPPLE & NOISE (max.)
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
300W Single Output with PFC Function
Note.5
Note.3
Note.2
90
100
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
3.3V
60A
0 ~ 60A
198W
80mVp-p
2.8 ~ 3.8V
1000ms, 50ms/230VAC
16ms/230VAC
85 ~ 264VAC
47 ~ 63Hz
PF>0.95/230VAC
5A/115VAC
35A/115VAC
<1.2mA / 240VAC
105 ~ 135% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
3.96 ~ 4.62V
Protection type : Shut down o/p voltage, re-power on to recover
PSU turns on : 3.3 ~ 5.6V ; PSU turns off : 0 ~ 1V
Load 35 15% or RTH2 50
-40 ~ +70
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
I/P-O/P:3KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11, ENV50204, EN55024, EN61000-6-2, heavy industry level, criteria A
176K hrs min.
199*105*41mm (L*W*H)
0.95Kg;15pcs/15.3Kg/0.69CUFT
HRP-300-3.3
80%
2.5%
0.5%
1.0%
0.03%/
5
5
(TSW1: detect on heatsink of power transistor)
(0 ~ 50 )
for 3.3V,5V,7.5V ; 95
(Refer to output load derating curve)
5V
60A
0 ~ 60A
300W
90mVp-p
4.3 ~ 5.8V
HRP-300-5
2.5A/230VAC
82%
6 ~ 7V
2.0%
0.5%
1.0%
MIL-HDBK-217F (25 )
I/P-FG:1.5KVAC
70A/230VAC
120 ~ 370VDC
16ms/115VAC at full load
PF>0.99/115VAC at full load
2500ms, 50ms/115VAC at full load
Fan on
HRP-300-7.5
7.5V
40A
0 ~ 40A
300W
100mVp-p
6.8 ~ 9V
86%
9.4 ~ 10.9V
2.0%
0.5%
1.0%
5
O/P-FG:0.5KVAC
for others (TSW2:
12V
27A
0 ~ 27A
324W
120mVp-p
10.2 ~ 13.8V
HRP-300-12
88%
14.4 ~ 16.8V
1.0%
0.3%
0.5%
detect on heatsink of
15V
22A
0 ~ 22A
330W
150mVp-p
13.5 ~ 18V
HRP-300-15
88%
18.8 ~ 21.8V
1.0%
0.3%
0.5%
H R P - 3 0 0
HRP-300-24
24V
14A
0 ~ 14A
336W
150mVp-p
21.6 ~ 28.8V
87%
30 ~ 34.8V
power diod
1.0%
0.2%
0.5%
e)
File Name:HRP-300-SPEC 2010-11-29
HRP-300-36
36V
9A
0 ~ 9A
324W
250mVp-p
28.8 ~ 39.6V
88%
41.4 ~ 48.6V
1.0%
0.2%
0.5%
HRP-300-48
48V
7A
0 ~ 7A
336W
250mVp-p
40.8 ~ 55.2V
89%
57.6 ~ 67.2V
s e r i e s
1.0%
0.2%
0.5%