SPECIFICATION
MODEL
OUTPUT
INPUT
PROTECTION
ENVIRONMENT
SAFETY &
EMC
(Note 7)
OTHERS
NOTE
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVERLOAD
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
HARMONIC CURRENT
EMS IMMUNITY
MTBF
DIMENSION
PACKING
OUTPUT NUMBER
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
RIPPLE & NOISE (max.)
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY(Typ.)
AC CURRENT (Typ.)
EMI CONDUCTION & RADIATION
125W Dual Output Switching Power Supply
Note.6
Note.6
Note.2
Note.3
Note.5
Note.4
RID-125-1224
CH1
12V
3.7A
1 ~ 7A
133.2W
120mVp-p
CH1: 11.4 ~ 13.2V
500ms, 20ms/230VAC
36ms/230VAC
88 ~ 132VAC / 176 ~ 264VAC selected by switch
47 ~ 63Hz
0.7Kg; 20pcs/15Kg/0.8CUFT
110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Protection type : Hiccup mode, recovers automatically after fault condition is removed
-20 ~ +70
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH
10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
I/P-O/P:3KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61000-6-2 (EN50082-2), heavy industry level, criteria A
218.2Khrs min.
199*98*38mm (L*W*H)
85%
3A/115VAC
COLD START 40A/230VAC
<2mA / 240VAC
CH1: 13.8 ~ 16.2V
2.0%
0.5%
1.0%
0.03%/
(0 ~ 50 )on CH1 output
(Refer to output load derating curve)
2A/230VAC
I/P-FG:1.5KVAC
MIL-HDBK-217F (25 )
30ms/115VAC at full load
CH2
24V
3.7A
0.4 ~ 5A
200mVp-p
+8,-5%
1.0%
5.0%
1200ms, 30ms/115VAC at full load
O/P-FG:0.5KVAC
RID-125-1248
CH1
12V
2.3A
1 ~ 7A
138W
120mVp-p
CH1: 11.4 ~ 13.2V
85%
CH1: 13.8 ~ 16.2V
2.0%
0.5%
1.0%
248 ~ 373VDC(300VAC peak 5sec. No damage)
CH2
48V
2.3A
0.2 ~ 2.5A
240mVp-p
+8,-5%
1.0%
5.0%
R I D - 1 2 5
RID-125-2448
CH1
24V
2A
0.5 ~ 4A
144W
200mVp-p
CH1: 22.8 ~ 26.4V
86%
CH1: 27.6 ~ 32.4V
1.0%
0.5%
1.0%
File Name:RID-125-SPEC 2010-10-18
CH2
48V
2A
0.2 ~ 2.5A
240mVp-p
4.0%
1.0%
3.0%
s e r i e s

Related parts for RID-125-1248

RID-125-1248 Summary of contents

Page 1

... HARMONIC CURRENT Compliance to EN61000-3-2,-3 EMS IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61000-6-2 (EN50082-2), heavy industry level, criteria A MTBF 218.2Khrs min. OTHERS DIMENSION 199*98*38mm (L*W*H) 0.7Kg; 20pcs/15Kg/0.8CUFT PACKING NOTE RID-125-1248 CH2 CH1 24V 12V 3.7A 2.3A 0 138W 200mVp-p 120mVp-p CH1: 11.4 ~ 13.2V 2.0% +8,-5% 2 ...

Page 2

... CH1 output I/P-FG:1.5KVAC O/P-FG:0.5KVAC MIL-HDBK-217F ( RID-125-2405 CH1 CH2 24V 7.8A 3A 125.4W 120mVp-p 80mVp-p CH1: 22.8 ~ 26.4V 2.0% 3.0% 0.5% 0.5% 1.0% 2.0% 248 ~ 373VDC(300VAC peak 5sec., no damage) 83% CH1: 27.6 ~ 32.4V File Name:RID-125-SPEC 2010-10- ...