DPCI-3U ETA-USA, DPCI-3U Datasheet - Page 2

no-image

DPCI-3U

Manufacturer Part Number
DPCI-3U
Description
Linear & Switching Power Supplies 180W DC Input
Manufacturer
ETA-USA
Datasheet

Specifications of DPCI-3U

Product
Switching
Output Power Rating
165 W
Number Of Outputs
4
Output Voltage (channel 1)
5 V
Output Current (channel 1)
33 A
Output Voltage (channel 2)
+ 3.3 V
Output Current (channel 2)
33 A
Dimensions
169.4 mm L x 40.52 mm W x 122.5 mm H
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Environmental Specification
Operating Temperature
Storage Temperature
Relative Humidity
Storage Humidity
Operational Vibration
Altitude
MTBF
Cooling
Function/Protection
Fusing
Transient Protection
Over Current/Short
Circuit Protection
Over Temperature Protection
Over Voltage Protection
Over/Under Shoot
Under Voltage Warning
Series Operation
Parallel Operation
Remote Sense
Signals, Indicators and Controls
Remote Enable
Remote Inhibit
Power Fail Warning
LED Indicator
Interconnect
I/O Connectors
47 Circuits ....................
Note: Use of the specified mating connector is required to insure proper "make/break"
Phone: 1-800-ETA-POWER, (408) 778-2793 Fax: (408) 779-2753
16170 Vineyard Blvd. Suite 180, Morgan Hill, CA 95037
ETA USA
sequential contact sequence.
(Refer to JE Outline Configuration or the chart in this data sheet for pin function identification)
0º – 50ºC ambient at full load, with specified airflow.
Derates linearly to 50% at 70ºC.
-40º – +75ºC
Up to 90% RH, non-condensing.
less than 85%/RH (non-condensing)
0.75G peak, 5 – 500Hz along three orthogonal axes.
Operating to 10,000 ft; Storage to 30,000 ft.
Designed for 150,000 hrs at 25ºC.
A minimum of 600 lfm direct forward airflow required to
achieve full rated power and specified MTBF. Consult
factory for derating guide-lines with reduced or
reversed airflow.
Internal line fuse provided, non-user serviceable. AC-
4.0A, 250V; DC- 10.0A.
MOV. Withstands transients as specified by IEEE C62.41
3KV (differential and common mode).
Current limit on all outputs. Automatic recovery when
overload is removed.
Internal temperature sensing. Causes all outputs to shut
down. Automatic recovery.
Non-crowbar type. Any output that exceeds 25% ±10% of
nominal Vout will cause all outputs to latch off. Remote
inhibit, enable or input recycle required resetting.
None at turn-on or turn-off.
Any output dropping below 10% of nominal triggers the
power fail warning signal.
available
not available
V1, V2, V3 outputs compensate for up to 0.25V total line
drop in the load cables. Outputs are internally sensed
if leads are opened.
Enabled by closed circuit or TTL logic 0.
Disabled by open circuit or TTL logic 1.
Enabled by open circuit or TTL logic 1.
Disabled by closed circuit or TTL logic 0.
Loss of input AC causes a TTL compatible signal to go
low >4msec prior to V1 or V2 output drop-ping out of
regulation. At AC turn-on, signal stays low until
outputs are in regulation. AC and DC input: PF signal
triggered by an under voltage condition on V1 or V2
outputs.
Dual LEDs. Green indicates input power ON and outputs
within regulation. Off or Amber indicates input and/or
output power fault.
Positronic Ind. P/N PCIH47M400A1.
Mates with PI P/N PCIH47F300A1.
Visit us at: www.eta-usa.com
email at: sales@eta-usa.com