PFC500-1024 POWER ONE, PFC500-1024 Datasheet - Page 2

no-image

PFC500-1024

Manufacturer Part Number
PFC500-1024
Description
Linear & Switching Power Supplies Single Output 375W (24V)
Manufacturer
POWER ONE
Type
Commercial, Industrialr
Datasheet

Specifications of PFC500-1024

Product
Switching
Brand/series
PFC500 Series
Configuration
Enclosed
Current, Output
21 A (Max.)
Frequency, Operating
100 kHz
Line Regulation
0.5 %
Load Regulation
0.2%
Mounting Type
Surface Mount
Number Of Outputs
1
Operation
Switching
Output
24 VDC @ 21 A
Power, Output
500 W
Primary Type
AC-DC
Special Features
Current Share, PFC, Power Fail, Power Good Signals, Remote Sense
Standards
UL Listed, CSA Certified, CE Marked
Temperature, Operating
0 to +50 °C
Time, Response
1 mS (Nom.)
Voltage, Input
85 to 264 VAC
Voltage, Output
24 VDC
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
AUG 01, 2003 revised to JUL 13, 2006
PDC500 Input Specifications
PARAMETER
Input Voltage - DC
Low Voltage Protection
Hold-up Time
Input Current
Input Protection
Inrush Surge Current
Output Specifications (PFC500 and PDC500)
PARAMETER
Efficiency
Minimum loads
Ripple and Noise
Output Power
Overshoot / Undershoot
Regulation
Transient Response
Turn-on Delay
Turn-on Rise Time
Interface Signals and Internal Protection (PFC500 and PDC500)
PARAMETER
Overvoltage Protection
Overload Protection
Overtemperature Protection
Remote Sense
Current Share
Inhibit
Input Power
Fail Warning
Power Good
Fan Voltage
CONDITIONS/DESCRIPTION
Continuous input range. Full power at 42-75 VDC.
Derate linearly from 40 VDC to 36 VDC, 400W.
Lowest DC input voltage.
At full load over DC input range.
48 VDC at full rated load.
Non-user serviceable internally located fuse.
Vin = 75 VDC, cold thermistor.
CONDITIONS/DESCRIPTION
Full rated load, 110 VAC (PFC500)/ 48VDC (PDC500).
Full load, 20 MHz bandwidth.
300 LFM forced air cooling required for operation. See optional fan.
Continuous power, multiple output models. PDC500 requires derating below
42 VDC; see PDC500 input specifications.
Output voltage overshoot/undershoot at turn-on.
Without connection of remote sense.
Recovery time, to within 1% of initial set point due to a 50-100% load change,
3% max. deviation.
Time required for initial output voltage stabilization.
Time required for output voltage to rise from 10% to 90%.
CONDITIONS/DESCRIPTION
Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition.
System shutdown due to excessive internal temperature, automatic reset.
Total voltage compensation for cable losses with respect to the main output.
Accuracy of shared current with up to 6 parallel units.
TTL compatible logic signal will inhibit outputs by the application of a logic low signal.
An open circuit or external TTL high signal allows normal operation.
TTL compatible logic signal. Time before regulation dropout due to
loss of input power at 110 VAC.
TTL compatible signal. Signal is low if main output is greater
or less than 10% of nominal. For models without the
“D” option, internal pull-up resistor is 1k
pull-up resistor is 475 . See Apps Note #P1 for details.
Provides 170mA current to user supplied fan if fan option is not selected.
Page 2 of 4
For “D” option,
PFC500/PDC500 Series Data Sheet
PFC/PDC500-1024
PFC/PDC500-1024
PFC500-1028
PFC500-1048
PFC/PDC500-1024
PFC500-1028
PFC500-1048
PFC500-1028
PFC500-1048
PFC/PDC500-1024
PFC500-1028
PFC500-1048
22.08
25.20
44.20
27.0
32.0
60.0
MIN
MIN
MIN
0.6
0.6
1.2
36
34
17
75
4
See Model Selection Charts
NOM
NOM
NOM
500
10
12
1
www.power-one.com
27.36
30.80
54.72
TBD
30.7
35.0
70.0
MAX
MAX
MAX
250
0.8
0.7
1.0
75
14
10
0
1
Amps
Watts
UNITS
UNITS
UNITS
VDC
VDC
ADC
A
Sec
mV
ms
ms
ms
ms
%
%
%
V
V
V
V
PK