DRH-120-48 Mean Well, DRH-120-48 Datasheet

Linear & Switching Power Supplies 120W 48V 2.5A

DRH-120-48

Manufacturer Part Number
DRH-120-48
Description
Linear & Switching Power Supplies 120W 48V 2.5A
Manufacturer
Mean Well
Datasheet

Specifications of DRH-120-48

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
SPECIFICATION
MODEL
OUTPUT
INPUT
PROTECTION
ENVIRONMENT
SAFETY &
EMC
(Note 4)
OTHERS
NOTE
AC CURRENT
INRUSH CURRENT (max.)
LEAKAGE CURRENT
OVERLOAD
OVER VOLTAGE
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMS IMMUNITY
MTBF
DIMENSION
PACKING
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
RIPPLE & NOISE (max.)
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE
LINE REGULATION
LOAD REGULATION
SETUP, RISE, HOLD UP TIME
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
EMI CONDUCTION & RADIATION
120W Single Output Industrial DIN RAIL Power Supply
Note.3
Note.2
DRH-120-24
24V
5A
0 ~ 5A
120W
80mVp-p
24 ~ 28V
1700ms, 120ms, 16ms/400VAC
340 ~ 550VAC
47 ~ 63Hz
85
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
105 ~ 160% rated output power
30 ~ 36V
Protection type : Shut down o/p voltage, re-power on to recover
-20 ~ +60
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH
Component:
UL60950-1 approved, IEC60950-1 CB approved by SIQ
I/P-O/P:3KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55011 (CISPR11), EN55022 (CISPR22), EN61204-3 Class B
Compliance to EN61000-4-2,3,4,5,6,8,11, ENV50204, EN61204-3, EN61000-6-2 (EN50082-2), heavy industry level, criteria A
178.7Khrs min.
65.5*125.2*100mm (W*H*D)
0.75Kg; 20pcs/16Kg/1.29CUFT
85%
0.65A/400VAC
COLD START 50A
<3.5mA / 530VAC
Protection type :
1.0%
0.5%
0.5%
0.03%/
5
(TSW) detect on heatsink of power switch
(0 ~ 50
(Refer to output load derating curve)
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting clip:
Constant current limiting, recovers automatically after fault condition is removed
I/P-FG:1.5KVAC
MIL-HDBK-217F (25 )
480 ~ 780VDC
0.6A/500VAC
1000ms, 120ms, 30ms/500VAC at full load
O/P-FG:0.5KVAC
DRH-120-48
48V
2.5A
0 ~2.5A
120W
80mVp-p
48 ~ 55V
59 ~ 66V
86%
1.0%
0.5%
0.5%
D R H - 1 2 0
Compliance to IEC60068-2-6
File Name:DRH-120-SPEC 2009-04-27
s e r i e s

Related parts for DRH-120-48

DRH-120-48 Summary of contents

Page 1

... Constant current limiting, recovers automatically after fault condition is removed 5 (TSW) detect on heatsink of power switch (Refer to output load derating curve) 0.03 500Hz, 2G 10min./1cycle, 60min. each along axes; Mounting clip: I/P-FG:1.5KVAC O/P-FG:0.5KVAC MIL-HDBK-217F ( DRH-120-48 48V 2.5A 0 ~2.5A 120W 80mVp 55V 1.0% 0.5% 0.5% 86% ...

Page 2

... PWM CONTROL O.T. (VERTICAL Case No.921A +V ADJ. TB2 LED Terminal Pin No. Assignment (TB1) Pin No. Assignment AC/L2 3 AC/L1 Terminal Pin No. Assignment (TB2) Pin No. Assignment 1,2 DC OUTPUT +V 3,4 DC OUTPUT -V fosc : 70KHz RECTIFIERS & FILTER DETECTION CIRCUIT CURRENT LIMIT O.V.P. File Name:DRH-120-SPEC 2009-04- Unit: ...