HRP-100-48 Mean Well, HRP-100-48 Datasheet

Linear & Switching Power Supplies 105.6W 48V 2.2A W/PFC Function

HRP-100-48

Manufacturer Part Number
HRP-100-48
Description
Linear & Switching Power Supplies 105.6W 48V 2.2A W/PFC Function
Manufacturer
Mean Well
Datasheet

Specifications of HRP-100-48

Product
Linear
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
SPECIFICATION
MODEL
OUTPUT
INPUT
PROTECTION
FUNCTION
ENVIRONMENT
SAFETY &
EMC
(Note 4)
OTHERS
NOTE
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
RIPPLE & NOISE (max.)
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVERLOAD
OVER VOLTAGE
OVER TEMPERATURE
REMOTE CONTROL
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
EMS IMMUNITY
MTBF
DIMENSION
PACKING
100W Single Output with PFC Function
Note.5
Note.3
Note.2
90 (3.3V ~ 7.5V) , 85 (12V ~ 48V) (TSW1 : detect on heatsink Q101 of power transistor)(optional)
Protection type :
3.3V
20A
0 ~ 20A
66W
80mVp-p
3.1 ~ 3.8V
+2.5,-3.5%
2500ms, 100ms/230VAC
50ms/230VAC
85 ~ 264VAC
47 ~ 63Hz
PF>0.95/230VAC
1.2A/115VAC
HRP-100-3.3
78%
35A/115VAC
<1mA / 240VAC
105 ~ 135% rated output power
Protection type : Constant current limiting for Vo=50 ~ 100% of rated voltage, recovers automatically after fault condition is removed
3.96 ~ 4.62V
Protection type : Shut down o/p voltage, re-power on to recover
RC+/RC- : 0 ~ 0.8V= power on ; 4 ~ 10V = power off
-40 ~ +60
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
I/P-O/P:3KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11, ENV50204, EN55024, EN61000-6-2, heavy industry level, criteria A
295.7K hrs min.
159*97*38mm (L*W*H)
0.38Kg; 24pcs/ 10.1Kg/0.76CUFT
0.5%
2.0%
0.04%/
(0 ~ 50
(Refer to output load derating curve)
5V
17A
0 ~ 17A
85W
80mVp-p
4.75 ~ 5.8V
HRP-100-5
83%
6 ~ 7V
Shut down
2.5%
0.5%
2.0%
0.6A/230VAC
I/P-FG:1.5KVAC
65A/230VAC
120 ~ 370VDC
MIL-HDBK-217F (25 )
20ms/115VAC at full load
PF>0.98/115VAC at full load
o/p voltage, recovers automatically after temperature goes down
2500ms, 100ms/115VAC at full load
HRP-100-7.5
7.5V
13.5A
0 ~ 13.5A
101.3W
100mVp-p
7.1 ~ 9V
84%
9.4 ~ 10.9V
2.5%
0.5%
1.5%
O/P-FG:0.5KVAC
12V
8.5A
0 ~ 8.5A
102W
120mVp-p
11.4 ~ 13.8V
HRP-100-12
87.5%
14.4 ~ 16.8V
1.5%
0.3%
0.8%
HRP-100-15
15V
7A
0 ~ 7A
105W
150mVp-p
14.25 ~ 18V
88%
18.8 ~ 21.8V
1.5%
0.3%
0.8%
H R P - 1 0 0
HRP-100-24
24V
4.5A
0 ~ 4.5A
108W
150mVp-p
22.8 ~ 28.8V
88.5%
30 ~ 34.8V
1.5%
0.2%
0.5%
File Name:HRP-100-SPEC 2010-11-29
HRP-100-36
36V
2.9A
0 ~ 2.9A
104.4W
200mVp-p
34.2 ~ 39.6V
89%
41.4 ~ 48.6V
1.5%
0.2%
0.5%
45.6 ~ 55.2V
HRP-100-48
48V
2.2A
0 ~ 2.2A
105.6W
240mVp-p
90%
57.6 ~ 67.2V
s e r i e s
1.5%
0.2%
0.5%

Related parts for HRP-100-48

HRP-100-48 Summary of contents

Page 1

... File Name:HRP-100-SPEC 2010-11- HRP-100-36 HRP-100-48 36V 48V 2. 2.2A 104.4W 105.6W 200mVp-p 240mVp-p 34.2 ~ 39.6V 45.6 ~ 55.2V 1.5% 1.5% 0.2% 0.2% 0.5% 0.5% ...

Page 2

... SWITCHING PFC O.L.P. O.T.P. PFC PWM CONTROL CONTROL Output Derating VS Input Voltage 100 (HORIZONTAL Case No.901I 152.5 78 159 150 117 RECTIFIERS & FILTER DETECTION CIRCUIT O.V.P. REMOTE CONTROL 85 100 125 135 155 INPUT VOLTAGE (V) 60Hz File Name:HRP-100-SPEC 2010-11- Unit: RC+ RC 264 ...