MAP130-1024C POWER ONE, MAP130-1024C Datasheet

no-image

MAP130-1024C

Manufacturer Part Number
MAP130-1024C
Description
Linear & Switching Power Supplies 130W 24/28V 6.2/5.4A WITH COVER
Manufacturer
POWER ONE
Type
Commercial, Industrialr
Datasheet

Specifications of MAP130-1024C

Product
Switching
Brand/series
MAP130 Series
Configuration
Open-Frame
Mounting Type
Panel
Number Of Outputs
1
Operation
Switching
Output
24 VDC @ 6.2 A/28 VDC @ 5.4 A
Power, Output
130 W
Primary Type
AC-DC
Special Features
Power Fail, Remote Sense
Voltage, Input
115/230 VAC
Voltage, Output
24/28 VDC
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Single Output Model Selection
MAP130-1005
MAP130-1012
MAP130-1024
NOTES: 1) Typical peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth.
Description
Power-One’s MAP130 Series of single and multiple output power supplies provide fully-regulated outputs with high
peak current capabilities in a compact 4.50" x 8.50" x 2.00" U-channel chassis. Other standard features include autos-
elect AC input, EMI level B filtering, power fail, thermal shutdown (with warning), remote sense, and metric and SAE
mounting inserts.
This convection-cooled series is designed for use in commercial and industrial environments in temperatures up to
50 °C. All products are approved to the latest international regulatory standards and display the CE Mark.
Multiple Output Model Selection
MCD10115 Rev. 1.3, 05-Feb-10
MODEL
MODEL
MAP130-4000
MAP130-4001
MAP130-4002
2) MAP130-1012 output currents are expressed as 12V/15V operation. MAP130-1024 output currents are expressed as 24V/28V operation.
3) Peak load for 60 seconds or less are acceptable, 10% duty cycle, maximum.
Model numbers highlighted in yellow or shaded are not recommended for new designs.
12V/15V
24V/28V
VOLTAGE
OUTPUT
VOLTAGE
OUTPUT
+12V
+24V
+12V
+12V
+12V
-12V
-12V
-12V
+5V
+5V
+5V
-5V
5V
11.4V to 15.75V
4.75V to 5.50V
22.5V to 30.0V
4.75V to 5.50V
11.5V to 12.5V
4.75V to 5.50V
23.0V to 25.0V
4.75V to 5.50V
11.5V to 12.5V
ADJUSTMENT
ADJUSTMENT
RANGE
RANGE
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
6.2A/5.4A (Note 2)
12A/10A (Note 2)
130W Continuous Output Power
CONTINUOUS
CURRENT
CURRENT
OUTPUT
26A
3.5A
20A
20A
20A
5A
1A
1A
1A
1A
5A
1A
1A
Page 1 of 4
CURRENT (NOTE 3)
PEAK CURRENT
13.8A/11A
6.8A/5.9A
(NOTE 1)
PEAK
30A
30A
10A
30A
30A
10A
1A
1A
5A
1A
1A
1A
1A
MAP130 AC-DC Series Data Sheet
Features
REGULATION
REGULATION
RoHS lead-solder-exemption compliant
Automatic 115/230 input voltage selection
All outputs fully regulated
Remote sense, overvoltage protection, and
overtemperature protection
Power Fail signal included
Greater than 100,000 Hour MTBF
U-Channel chassis: 8.50" x 4.50" x 2.00"
(215.9mm x 114.3mm x 50.8mm)
Optional cover
Metric and SAE mounting inserts
0.2%
0.2%
0.2%
0.2%
0.5%
0.5%
0.5%
0.2%
0.5%
0.5%
0.5%
0.2%
0.5%
0.5%
0.5%
LINE
LINE
REGULATION
REGULATION
LOAD
LOAD
1%
1%
1%
1%
2%
2%
2%
1%
2%
2%
2%
1%
2%
2%
2%
NOISE %p-p (NOTE 1)
NOISE %p-p (NOTE 2)
TYPICAL RIPPLE &
TYPICAL RIPPLE &
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
www.power-one.com
-11.6V to -12.4V
-11.6V to -12.4V
-11.6V to -12.4V
-11.6V to -12.4V
11.75V to 12.0V
12.0V to 12.2V
23.9V to 24.1V
11.6V to 12.4V
INITIAL SETTING
23.9V to 24.1V
11.9V to 12.1V
INITIAL SETTING
-4.8V to -5.2V
5.1V to 5.2V
5.1V to 5.2V
5.1V to 5.2V
5.1V to 5.2V
ACCURACY
ACCURACY

Related parts for MAP130-1024C

MAP130-1024C Summary of contents

Page 1

... NOTES: 1) Typical peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth. 2) MAP130-1012 output currents are expressed as 12V/15V operation. MAP130-1024 output currents are expressed as 24V/28V operation. 3) Peak load for 60 seconds or less are acceptable, 10% duty cycle, maximum. Multiple Output Model Selection ...

Page 2

... Efficiency Full Load, 115VAC. Varies with distribution of loads among outputs. Minimum Loads MAP130-1012. MAP130-1024. MAP130-1005 and all multiple output models, main channel only. Ripple and Noise Full load, 20MHz bandwidth. Output Power Continuous output power, all multiple output models. Peak output power (60s maximum, 10% duty cycle), all multiple output models. ...

Page 3

... Warning prior to system shutdown due to excessive internal temperatures. (Note 2) Shifts Power Fail signal to a logic LO state. NOTES: 1) Power Fail not available on MAP130-1012 and MAP130-1024. 2) MAP130-1012 and MAP130-1024 have overtemperature protection, but do not have the warning feature. Safety, Regulatory, and EMI Specifications PARAMETER CONDITIONS/DESCRIPTION Agency Approvals UL1950 ...

Page 4

... TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. MCD10115 Rev. 1.3, 05-Feb-10 MAP130 AC-DC Series Data Sheet WEIGHT: 2.5 lb (1.13 kg) 0.045" (1.1mm) SQUARE PINS ON 0.156" (3.96mm) CENTERS; ...

Related keywords