MPU150-3300G POWER ONE, MPU150-3300G Datasheet - Page 2

no-image

MPU150-3300G

Manufacturer Part Number
MPU150-3300G
Description
Linear & Switching Power Supplies
Manufacturer
POWER ONE
Datasheet

Specifications of MPU150-3300G

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
MCD10009 Rev. 1.0, 15-Oct-07
DC Input Model Selection -
MDU150-3300
MDU150-4000
MDU150-4230
MDU150-4350
MDU150-4530
NOTES: 1) The MPU/MDU150 products require a minimum of 300 LFM of forced-air cooling
Ordering Information:
OPTIONS
Metric Mounting
RoHS lead solder exemption
RoHS compliant for all 6 substances
MPU150 Input Specifications
PARAMETER
Input Voltage - AC
Input Frequency
Hold-up Time
Input Current
Input Protection
Inrush Surge Current
Power Factor
Operating Frequency
MODEL
2) Maximum peak-to-peak noise expressed as a percentage of output voltage,
3) Total current between V1 and V2 is 30A, maximum rating.
20 MHz bandwidth.
under ALL load conditions. It is recommended that the airflow be applied from the
input side of the power supply blowing towards the output.
VOLTAGE
OUTPUT
+3.3V
+2.5V
+3.3V
+3.3V
+3.3V
+12V
+12V
+5V
+5V
12V
12V
+5V
12V
12V
+5V
12V
12V
5V
5V
CONDITIONS/DESCRIPTION
Continuous input range.
AC input.
After last AC line peak at 150 watts.
85 VAC at full rated load.
Non-user serviceable internally located AC input line fuse.
Internally limited by thermistor. Vin = 230 VAC, one cycle, 25°C.
Per EN61000-3-2.
Switching frequency of main output transformer.
Switching frequency of secondary transformer.
Switching frequency of Power Factor Correction circuit.
3.15V to 3.80V
10.8V to 13.2V
10.8V to 13.2V
10.8V to 13.2V
10.8V to 13.2V
10.8V to 13.2V
3.15V to 3.60V
10.8V to 13.2V
10.8V to 13.2V
2.25V to 3.0V
3.15V to 3.8V
3.15V to 3.8V
5.0V to 5.5 V
5.0V to 5.5V
5.0V to 5.5V
5.0V to 5.5V
5.0V to 5.5V
5.0V to 5.5V
ADJUSTMENT
150W WITH 300 LFM FORCED-AIR COOLING
ISOLATED V3 AND V4 CAN BE USED AS POSITIVE OR NEGATIVE OUTPUTS
RANGE
N/A
SUFFIXES TO ADD TO PART NUMBER
Add “M” as a suffix to the model number to order chassis with M4 x 0.7 mounting inserts. Metric mounting
inserts are standard for single-output models MPU150-S259, MPU150-S261, and MPU150-S262.
No RoHS suffix character required.
Add “G” as the last character of the part number.
CURRENT (NOTE 1)
30A (Note 3)
30A (Note 3)
15A (Note 3)
30A (Note 5)
15A (Note 5)
30A (Note 3)
15A (Note 3)
3A (Note 4)
3A (Note 4)
3A (Note 4)
3A (Note 4)
OUTPUT
35A
20A
2A
8A
3A
2A
3A
2A
Page 2 of 6
REGULATION
0.6%
0.4%
0.4%
0.4%
0.4%
0.4%
0.4%
1.5%
1.5%
0.4%
0.6%
0.4%
0.4%
LINE
2%
1%
1%
1%
7%
7%
MPU150/MDU150 Series Data Sheet
4) Total current between V3 and V4 is 5A, maximum rating.
5) Total current between V1 and V2 is 40A, maximum rating
All other models
MPU150-4350
REGULATION
MPU150
1.5%
1.5%
1.5%
1.5%
LOAD
3%
3%
1%
1%
1%
1%
2%
1%
1%
1%
7%
7%
1%
7%
7%
%Pk-Pk (NOTE 2)
RIPPLE & NOISE
17.5
0.95
100
MIN
85
47
20
65
1.5%
1.5%
1.5%
1%
1%
1%
1%
1%
1%
2%
1%
1%
1%
1%
1%
1%
1%
1%
1%
NOM
60
www.power-one.com
11.76V to 12.24V
11.94V to 12.06V
11.94V to 12.06V
11.94V to 12.06V
11.94V to 12.06V
11.94V to 12.06V
11.94V to 12.06V
11.94V to 12.06V
3.28V to 3.32V
4.98V to 5.02V
4.98V to 5.02V
4.98V to 5.02V
2.49V to 2.51V
3.28V to 3.32V
3.28V to 3.32V
5.00V to 5.04V
4.98V to 5.02V
3.28V to 3.32V
INITIAL SETTING
4.98V to 5.0V
ACCURACY
MAX
264
120
3.0
63
35
90
A
W/VA
UNITS
VAC
A
kHz
ms
RMS
Hz
PK

Related parts for MPU150-3300G