GLC65B SL Power, GLC65B Datasheet

Linear & Switching Power Supplies 65W +5.1/+15/-15V

GLC65B

Manufacturer Part Number
GLC65B
Description
Linear & Switching Power Supplies 65W +5.1/+15/-15V
Manufacturer
SL Power
Series
GLCr
Datasheet

Specifications of GLC65B

Product
Switching
Commercial/medical
Commercial
Output Power Rating
36 W
Input Voltage
90 VAC to 264 VAC
Number Of Outputs
3
Output Voltage (channel 1)
5.1 V
Output Current (channel 1)
7 A
Output Voltage (channel 2)
15 V
Output Current (channel 2)
2.5 A
Output Voltage (channel 3)
- 15 V
Output Current (channel 3)
2 A
Mounting Style
Chassis
Dimensions
127 mm L x 76.2 mm W
Open Frame/enclosed
Open Frame
Output Type
Triple Output
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
• 65 Watt Wide Range Input
• High Efficiency (Up to 90%)
• Universal input 90-264 Vac
• 2-year warranty
• Also available in single outputs
• Conducted EMI complies with FCC Class B and
• Exempt from line harmonics standard EN61000-3-2
• Commercial Approved to UL1950, CSA-C22.2 No. 950,
• Medical Approved to UL2601-1, CSA 22.2 No. 601.1, and
• RoHS Compliant (G suffix)
SPECIFICATIONS
Ac Input
90-264 Vac, 47-63 Hz single phase.
Output Power
Total continuous output power is 60 W, 75 W peak for 60 s 10% duty cycle.
Total continuous rating with 150 LFM of air is 70 W.
Input Current
Units are exempt from input current harmonic requirements of EN61000-3-2
when output power is less than 62W. Maximum input current at minimum
input voltage and output overload will be less than 2.0 A.
Inrush Current
Inrush is limited by internal thermistor. The inrush at 240 Vac, averaged over
the first ac half-cycle under cold start conditions will not exceed 37 A.
Input Protection
Internal AC fuse provided on all units. Designed to blow only if a catastrophic
failure occurs in the unit -- Fuse does not blow on short circuit or unsustained
overload.
Holdup Time
Output voltage stays within regulation for 20 ms from loss of ac input at 65 W
load, from 120 Vac input.
Efficiency
80% minimum.
Overload Protection
Fully protected against short circuit and output overload. Short circuit
protection is cycling type power limit and will automatically recover after
removal of fault.
Overvoltage Protection
Built in with firing point set. OVP firing reduces output to less than 50% of
nominal voltage in less than 50 ms.
Output Noise
0.5% rms, 1% pk-pk, 20 MHz Bandwidth, differential mode. Measured with
scope probe directly across output terminals of the power supply with load
terminated with 1μF capacitor.
Transient Response
Main Output - 500 μs typical response time for return to within 0.5% of final
value for a 50% load step within the regulation limits of minimum and maxi-
mum load, ∆i/∆t< 0.2 A/μs. Maximum voltage deviation is 3.5%.
Summary:
CISPR 22 Class B (Commercial models) and
CISPR 11 Class B (Medical models)
EN60601-1• Medical Approved to UL2601-1, CSA 22.2 No. 601.1,
MULTIPLE OUTPUT GLOBAL PERFORMANCE SWITCHERS
All specifications are typical at nominal input, full load at 25
marked to LVD
GLC65 Commercial/GLM65 Medical
65 Watt Multiple Output Global Performance Switchers
O
C unless otherwise stated
Minimum Load
No minimum load required on any output. However, regulation limits may be
exceeded if extreme conditions are applied. Contact factory for assistance.
Temperature Coefficient: 0.03%°C typical on all outputs.
Voltage Adjustment
Units provided with one potentiometer capable of adjusting all 3 outputs a mini-
mum of +/- 5% from nominal setting.
EMI / EMC Compliance:
All models include built-in EMI filtering to meet EMC requirements of IEC601-1-2.
PERFORMANCE
Conducted Emissions GLC65
Conducted Emissions GLM65
Static Discharge
RF Field Susceptibility
Fast Transients/Bursts
Surge Susceptibility
Conducted RF Susceptibility
Voltage Sags & Surges
Line Frequency Harmonics
GLC65 Commercial - Safety
SL Power Electronics Corp declares under our sole responsibility that all models
are in conformity with the applicable requirements of EN60950 following the
provisions of the Low Voltage Directive 73/23/EEC. All models are approved to
UL1950 (with no D3 deviations), CSA22.2 No. 950-95 3rd edition, Level 3, IEC950,
EN60950. CB certificate available.
Commercial Leakage Current
Less then 500 μA @ 120 Vac. Less then 1.2 mA @ 240 Vac.
GLM65 Medical - Safety
Approvals: All models are certified to be in compliance with the applicable require-
ments of UL2601-1, CSA 22.2 No. 601.1, IEC 601-1 (1988), EN 60601-1: 1990.
Medical Leakage Current
80 μA under normal conditions (132 Vac @ 60 Hz). Maximum under single fault
conditions (264 Vac @ 60 Hz) is 180 μA.
EMC STANDARD
EN55022 Class B; FCC Class B
EN55011 Class B; FCC Class B
EN61000-4-2, Level 3
EN61000-4-3, Level 3
EN61000-4-4, Level 3
EN61000-4-5, Level 3
EN61000-4-6, 3V, 80%
EN61000-4-11
EN61000-3-2 Class A (>62Wout)
Exempt (<62Wout)

Related parts for GLC65B

GLC65B Summary of contents

Page 1

... Voltage Sags & Surges Line Frequency Harmonics GLC65 Commercial - Safety SL Power Electronics Corp declares under our sole responsibility that all models are in conformity with the applicable requirements of EN60950 following the provisions of the Low Voltage Directive 73/23/EEC. All models are approved to UL1950 (with no D3 deviations), CSA22.2 No. 950-95 3rd edition, Level 3, IEC950, EN60950 ...

Page 2

... Commercial Medical Model Model Output No. GLC65A GLM65A GLC65B GLM65B GLC65D GLM65D GLC65E GLM65E GLC65G GLM65G GLC65H GLM65H Notes: A. Continuous individual output ratings for unrestricted convection cooling. Combination of individual output loads must not exceed total power rating. B. Peak rating for 60 s 10% duty cycle or continuous rating 150 LFM forced air cooling. ...