SCN-600-12 Mean Well, SCN-600-12 Datasheet

no-image

SCN-600-12

Manufacturer Part Number
SCN-600-12
Description
Linear & Switching Power Supplies 600W 12V 50A W/PARALLEL FUNCTION
Manufacturer
Mean Well
Datasheet

Specifications of SCN-600-12

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
SPECIFICATION
ORDER NO.
OUTPUT
INPUT
PROTECTION
ENVIRONMENT
SAFETY &
EMC
(Note. 4)
OTHERS
NOTE
INRUSH CURRENT (max.)
LEAKAGE CURRENT
OVERLOAD
OVER VOLTAGE
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
MTBF
DIMENSION
PACKING
SAFETY MODEL NO.
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
RIPPLE & NOISE (max.)
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE
LINE REGULATION
LOAD REGULATION
SETUP, RISE, HOLD UP TIME
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
EMS IMMUNITY
SPECIAL FUNCTION
600W Single Output With Parallel Function
Note.2
Note.3
SCN-600-05
600S-N005
5V
100A
0 ~ 100A
500W
100mVp-p
800ms, 50ms, 16ms at full load
90 ~ 130VAC / 180 ~ 260VAC
47 ~ 63Hz
77%
DC voltage adj., Remote sensing, remote control, parallel operation (refer to terminal instruction manual)
11A / 115VAC
101 ~ 115%
Protection type : Current limiting, delay shut down o/p voltage, re-power on to recover
110 ~ 135% follow to output set up point
Protection type : Shut down o/p voltage, re-power on to recover
>100
Protection type : Shut down o/p voltage, re-power on to recover
-10 ~ +65
20% ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH
10 ~ 200Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, CSA22.2, IEC60950 approved
I/P-O/P, I/P-FG:1500VAC
I/P-O/P, I/P-FG, 100M Ohms / 500VDC / 25 / 70% RH
Compliance to FCC part 15 class A
----
----
120Khrs min. MIL-HDBK-217F (25 )
291*132*68mm (L*W*H)
2.6kg; 8pcs/ 24kg/ CARTON
60A / 230VAC
3.5mA / 240VAC
5.0% typical adjustment by potentiometer
1.5%
0.5%
1.0%
0.04% /
/ measure by heat sink, near transformer
(Refer to output load derating curve)
(0 ~ 50 )
7.0A / 230VAC
SCN-600-12
600S-N012
12V
50A
0 ~ 50A
600W
120mVp-p
80%
1.0%
0.5%
0.5%
110 ~ 135% rated output power
selected by switch,
SCN-600-15
81%
600S-N015
15V
40A
0 ~ 40A
600W
150mVp-p
1.0%
0.5%
0.5%
20~100% adjustment by 1~5VDC external control
260 ~ 370VDC
SCN-600-18
82%
600S-N018
18V
33A
0 ~ 33A
594W
180mVp-p
1.0%
0.5%
0.5%
S C N - 6 0 0
85%
SCN-600-24
600S-N024
24V
25A
0 ~ 25A
600W
240mVp-p
1.0%
0.5%
0.5%
File Name:SCN-600-SPEC 2008-05-06
SCN-600-48
87%
600S-N048
48V
12A
0 ~ 12A
576W
480mVp-p
1.0%
0.5%
0.5%
s e r i e s

Related parts for SCN-600-12

SCN-600-12 Summary of contents

Page 1

... MTBF 120Khrs min. MIL-HDBK-217F (25 ) DIMENSION 291*132*68mm (L*W*H) OTHERS PACKING 2.6kg; 8pcs/ 24kg/ CARTON SPECIAL FUNCTION DC voltage adj., Remote sensing, remote control, parallel operation (refer to terminal instruction manual) NOTE SCN-600-12 SCN-600-15 600S-N012 600S-N015 12V 15V 50A 40A 0 ~ 50A 0 ~ 40A 600W 600W ...

Page 2

... Single Output With Parallel Function Mechanical Specification INPUT 9 Derating Curve 100 50 - 291 200 199.5 #6-32-4 M3(NUT)x3H-4 291 250 M3(NUT)x3H-4 BOTTOM SIDE External DC Control VS Output Voltage Vout 100 50 Air flow direction M6.0 O.V.P. non-linear EXTERNAL VOLTAGE(Typical) File Name:SCN-600-SPEC 2008-05- Unit:mm LED V ADJ POS+ NEG- V ...

Page 3

Parallel (N+1) With PFC Function Control terminal instruction manual LOAD VS+ VS- VCI VCO PG PAR GND GND INH USING INTERNAL VOLTAGE CONTROL REMOTE SENSING : LED OFF GOOD FAIL : LED ON LOAD VS+ VS+ VS- VS- VCI ...

Related keywords