LTC490CS8#PBF Linear Technology, LTC490CS8#PBF Datasheet - Page 8

IC TXRX RS485 LOW POWER 8-SOIC

LTC490CS8#PBF

Manufacturer Part Number
LTC490CS8#PBF
Description
IC TXRX RS485 LOW POWER 8-SOIC
Manufacturer
Linear Technology
Type
Transceiverr
Datasheet

Specifications of LTC490CS8#PBF

Number Of Drivers/receivers
1/1
Protocol
RS422, RS485
Voltage - Supply
4.75 V ~ 5.25 V
Mounting Type
Surface Mount
Package / Case
8-SOIC (3.9mm Width)
No. Of Drivers
1
Supply Voltage Range
4.75V To 5.25V
Driver Case Style
SOIC
No. Of Pins
8
Operating Temperature Range
0°C To +70°C
Msl
MSL 1 - Unlimited
Termination Type
SMD
Rohs Compliant
Yes
Filter Terminals
SMD
Ic Interface Type
RS422, RS485
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
LTC490CS8#PBFLTC490CS8
Manufacturer:
LINEAR/凌特
Quantity:
20 000
Company:
Part Number:
LTC490CS8#PBF
Manufacturer:
IDT
Quantity:
87
Company:
Part Number:
LTC490CS8#PBF
Manufacturer:
LINEAR/凌特
Quantity:
20 000
APPLICATIO S I FOR ATIO
cable is lightly loaded (470 ), the signal reflects in phase
and increases the amplitude at the driver output. An input
frequency of 30kHz is adequate for tests out to 4000 feet
of cable.
AC Cable Termination
Cable termination resistors are necessary to prevent un-
wanted reflections, but they consume power. The typical
differential output voltage of the driver is 2V when the
cable is terminated with two 120
33mA of DC current to flow in the cable when no data is
being sent. This DC current is about 60 times greater than
the supply current of the LTC490. One way to eliminate the
unwanted current is by AC coupling the termination resis-
tors as shown in Figure 10.
The coupling capacitor must allow high frequency energy
to flow to the termination, but block DC and low frequen-
cies. The dividing line between high and low frequency
depends on the length of the cable. The coupling capacitor
must pass frequencies above the point where the line
represents an electrical one-tenth wavelength. The value
of the coupling capacitor should therefore be set at 16.3pF
per foot of cable length for 120 cables.
LTC490
8
Figure 10. AC Coupled Termination
C = LINE LENGTH (FT) 16.3pF
U
C
120
U
RECEIVER
W
resistors, causing
LTC490 • F10
RX
U
With the coupling capacitors in place, power is consumed
only on the signal edges, and not when the driver output
is idling at a 1 or 0 state. A 100nF capacitor is adequate for
lines up to 4000 feet in length. Be aware that the power
savings start to decrease once the data rate surpasses
1/(120
Fault Protection
All of LTC’s RS485 products are protected against ESD
transients up to 2kV using the human body model (100pF,
1.5k ). However, some applications need more
protection. The best protection method is to connect a
bidirectional TransZorb
(Figure 11). A TransZorb is a silicon transient voltage
suppressor that has exceptional surge handling capabili-
ties, fast response time, and low series resistance. They
are available from General Instruments, GSI and come in
a variety of breakdown voltages and prices. Be sure to pick
a breakdown voltage higher than the common mode
voltage required for your application (typically 12V). Also,
don’t forget to check how much the added parasitic
capacitance will load down the bus.
TransZorb is a registered trademark of General Instruments, GSI
Figure 11. ESD Protection with TransZorbs
C).
DRIVER
®
from each line side pin to ground
Y
120
Z
LTC490 • F11
490fb

Related parts for LTC490CS8#PBF