201 Staco Energy Products Co., 201 Datasheet - Page 3

no-image

201

Manufacturer Part Number
201
Description
Transformer, Var.; 0 to 120V Vo; 2A Io; 0.24kVA; 120V Vi; Panel; 50/60Hz; CW/CCW
Manufacturer
Staco Energy Products Co.
Type
Variabler
Datasheet

Specifications of 201

Brand/series
200 Series
Capacity
0.24 kVA (Max.)
Configuration
Open Frame
Current, Secondary
2 A
Dimensions
1.88"L×2.93"D
Frequency
50/60 Hz
Knob Rotation
Clockwise
Mounting Type
Panel/Chassis
Number Of Outlets
1
Phase
1
Power, Rating
0.24/0.26 kVA (Constant Current Load), 0.3 kVA (Constant Impedance Load)
Termination
Solder Lug/Quick-Connect
Voltage, Primary
120 VAC
Voltage, Secondary
0-120/0-132 VAC
Weight
2 lbs.
Lead Free Status / Rohs Status
RoHS Compliant part

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
201
Manufacturer:
PLM
Quantity:
36
Part Number:
201
Manufacturer:
ALTERA
0
Part Number:
201
Manufacturer:
ST
0
Part Number:
201
Manufacturer:
ST
0
Part Number:
201-001E
Manufacturer:
Optek
Quantity:
100
Part Number:
201-1040-01R
Manufacturer:
AVNET
Quantity:
20 000
Part Number:
201-401-90-200-202
Manufacturer:
RFPowerComponents
Quantity:
194
Part Number:
2010
Manufacturer:
BT
Quantity:
6
Part Number:
2010 5% 0R
Manufacturer:
EVEROHMS
Quantity:
4 656
Part Number:
2010-0.01RF
Manufacturer:
VISHA
Quantity:
20 000
Part Number:
2010-0.033RF
Manufacturer:
VISHA
Quantity:
20 000
Part Number:
2010-0.039RF
Manufacturer:
VISHA
Quantity:
20 000
Part Number:
2010-0.047RF
Manufacturer:
VISHA
Quantity:
20 000
100/200 Series
++ Line to line voltage
π
PART NO.
291-2
291-3
291
Jumper provided in the standard common position and should be moved or removed as required.
If ganged units are used in a system that ordinarily has a common neutral or ground between source and load, the neutral or ground must be connected to the com-
mon terminals of the variable transformer assembly. If the system has no neutral, the load must be balanced or the transformers will be damaged.
WIRING
Delta π
Single
Phase
Single
Phase
Series
Phase
Phase
Wye π
Three
Three
Open
201-3
221-B
VOLTS
120++
240++
120
240
INPUT
HERTZ
50/60
50/60
50/60
Single Unit
60
60
60
60
Two and Three Gang Units
VOLTS
0-120
0-132
0-240
0-264
0-120
0-132
0-240
AMPS
MAX
3.0
3.0
3.0
3.0
3.0
3.0
3.0
CONSTANT
CURRENT
LOAD
OUTPUT
MAX
0.36
0.40
0.72
0.79
0.62
0.69
1.25
KVA
AMPS
MAX
3.5
3.5
3.5
3.5
120V
IMPEDANCE
CONSTANT
LOAD
MAX
0.42
0.84
0.73
1.45
KVA
INCREASE
ROTATION
VOLTAGE
SHAFT
CCW
CCW
CCW
CCW
View from
Base End
FOR
CW
CW
CW
CW
CW
CW
CW
2-1-2
1-2-1
4-1-4
2-2-2
1-1-1
TERMINAL CONNECTIONS
Input
1-2
1-2
1-4
2-2
1-1
4-4
As Viewed from Base End
(For increasing Voltage)
Jumper• Output
1-1-1
2-2-2
1-1
2-2
1-1
1-1
2-2
1-1
240V
3-1-3
3-2-3
3-1-3
3-3-3
3-3-3
1-3
2-3
1-3
3-3
3-3
3-3
221-B-2, 252-2
221-B-3, 252-3
221-B, 252
171-2, 201-2
171-3, 201-3
171, 201
TYPE
TYPE
291
291-2
291-3
(Pg 8 & 9)
SCHE-
MATIC
1 & 4
1 & 5
1 & 6
1
1.88” [47.6]
2.12” [54.0]
2.31” [58.7]
4.66” [118.3]
7.38” [187.2]
5.16” [131.0]
8.12” [206.4]
5.59” [142.1]
8.81” [223.8]
A
B
2 1/2
5 1/2
5 1/2
8 1/4
LBS.
NET