ZE-NJ-2S Omron Automation, ZE-NJ-2S Datasheet - Page 3

no-image

ZE-NJ-2S

Manufacturer Part Number
ZE-NJ-2S
Description
Switch, Enclosed, Limit, 15A 125/250 VAC, 4.0"H, 150 OPERATING FORCE
Manufacturer
Omron Automation
Datasheet

Specifications of ZE-NJ-2S

Operating Force
5.3 Oz.
Temperature, Operating
-10 to +80 °C
Lead Free Status / Rohs Status
RoHS Compliant part
ZE/ZV/XE/XV
Note: 1. The above figures are initial values.
Contact Form
Degree of protection
Life expectancy (see note 3)
Operating speed
Operating frequency
Rated frequency
Insulation resistance
Contact resistance
Terminal temperature rise
Dielectric strength
Vibration resistance
Shock resistance (see note 4)
Ambient temperature (see note 1)
Ambient humidity
Weight
OF max.
RF min.
PT max.
OT min.
MD max.
OP
OF max.
RF min.
PT max.
OT min.
MD max.
OP
Model
Model
Characteristics
Operating Characteristics
ZE-j, ZV-j, ZV2-j
XE-j, XV-j, XV2-j
2. IP65 for jE-N models and IP60 for jE-Q models.
3. Life expectancy values are calculated at an operating temperature of 5 C to 35 C, and an operating humidity of 40% to 70%. Con-
4. At the operation limit positions.
5. Only for plunger, sealed plunger, roller arm lever, and sealed roller arm lever.
6. Only for crossroller plunger, sealed crossroller plunger, roller plunger, and sealed roller plunger.
tact your OMRON sales representative for more detailed information on other operating environments.
2.45 to 3.43 N
1.12 N
0.4 mm
5.5 mm
0.05 mm
38.2 0.8 mm
5.00 N
1.12 N
0.9 mm
3.6 mm
0.47 mm
49.7 1 mm
XE-Q21-2
ZE-Q-2
5.59 N
1.67 N
4 mm
6 mm
0.4 mm
---
COM
5.00 N
1.12 N
0.9 mm
5.5 mm
0.47 mm
ZE-QA2-2
IP65 (see note 2)
Mechanical:
Zj: 10,000,000 operations min.
Xj: 1,000,000 operations min.
Electrical:
Zj: 500,000 operations min., for 15 A, 250 VAC resistive load
Xj: 100,000 operations min., for 10 A, 125 VDC resistive load
Plunger type: 0.01 mm to 0.5 m/s
Lever type: 0.02 mm to 0.5 m/s
Mechanical: 120 operations/min
Electrical:
50/60 Hz
100 M min. (at 500 VDC)
15 m max. (initial value)
50 max.
1,000 VAC, 50/60 Hz for 1 min between terminals of the same polarity
2,000 VAC, 50/60 Hz for 1 min between current-carrying metal part and ground, and between
each terminal and non-current-carrying metal part (1,500 VAC for Zj models and Xj models)
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude (see note 4)
Destruction: 1,000 m/s
Malfunction: 100 m/s
Operating: –10 C to 80 C (with no icing)
Operating: General-purpose type: 85% max.
Approx. 260 to 280 g
XE-Q-2
Sealed type:
20 operations/min
6.47N
1.67 N
6 mm
5.5 mm
0.72 mm
NC
NO
XE-QA2-2
2
2.45 to 3.43 N
1.12 N
0.5 mm
3.6 mm
0.05 mm
49.7 1 mm
min. (see note 5), 50 m/s
2
min.
ZE-Q22-2
5.59 N
1.67 N
4 mm
6 mm
0.4 mm
95% max.
ZE-QA277-2
5.00 N
1.12 N
0.9 mm
3.6 mm
0.47 mm
2
min. (see note 6)
XE-Q22-2
6.47 N
1.67 N
6 mm
5.5 mm
0.72 mm
XE-QA277-2
2.45 to 3.43 N
1.12 N
0.5 mm
3.6 mm
0.05 mm
49.7 1 mm
ZE/ZV/XE/XV
7.85 N
2.35 N
2 mm
5 mm
0.1 mm
45.8 0.8 mm
ZE-Q21-2
ZE-N-2
3

Related parts for ZE-NJ-2S