TL-W3MC1 Omron Automation, TL-W3MC1 Datasheet - Page 2

no-image

TL-W3MC1

Manufacturer Part Number
TL-W3MC1
Description
Sensor; Inductive Sensing Mode; NPN-NO; 0.12; 10 to 30 VDC; Flat, Rectangular
Manufacturer
Omron Automation
Type
Inductiver
Datasheet

Specifications of TL-W3MC1

Body Style
Rectangular
Current, Rating
15 mA (Max.) (Consumption)
Current, Switching
100 mA
Dimensions
1.06 in. L x 0.39 in. W x 0.24 in. H
Frequency, Switching
600 Hz (Response)
Function
Proximity
Indicator
LED Red (Target Present)
Ip Rating
IP67
Length, Cable
2 mm
Material, Housing
ABS Plastic
Mounting Type
Bracket/DIN Rail
Output
NPN-NO
Primary Type
Proximity
Range, Measurement
0.12 In.
Standards
UL Listed, CSA Certified
Technology
Inductive
Temperature, Range, Operating Ambient
-25 to +70 °C
Termination
3-Wire Cable
Voltage, Supply
24 VDC
Voltage, Switching
1 V
Supply Voltage Range
10-30 VDC
Load Rating
100 mA (DC)
Approvals
CE Mark
Lead Free Status / Rohs Status
RoHS Compliant part

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TL-W3MC1
Manufacturer:
OMRON
Quantity:
1 000
Part Number:
TL-W3MC1
Manufacturer:
APEM
Quantity:
238
Part Number:
TL-W3MC1 2M
Manufacturer:
OMRON
Quantity:
500
Part Number:
TL-W3MC1 5M
Manufacturer:
OMRON
Quantity:
500
Part Number:
TL-W3MC1-R 2M
Manufacturer:
OMRON
Quantity:
500
Ratings and Specifications
DC 2-Wire Models
* The response frequency is an average value.
Item
Sensing distance
Set distance
Differential travel
Detectable object
Standard sensing object
Response frequency
Power supply voltage
(operating voltage range)
Leakage current
Con-
trol
output
Indicators
Operation mode (with sensing
object approaching)
Protection circuits
Ambient temperature range
Ambient humidity range
Temperature influence
Voltage influence
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Degree of protection
Connection method
Weight (packed state)
Materials
Accessories
Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance.
Load current
Residual voltage
Case
Sensing surface
*
Model
5 mm 10%
0 to 4 mm
10% max. of sensing distance
Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page
5.)
Iron, 18
500 Hz
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
0.8 mA max.
3 to 100 mA
3.3 V max. (under load current of 100 mA with cable length of 2 m)
D1 Models: Operation indicator (red), Setting indicator (green)
D2 Models: Operation indicator (red)
D1 Models: NO
D2 Models: NC
Load short-circuit protection, Surge suppressor
Operating/Storage: 25 to 70 C (with no icing or condensation)
Operating/Storage: 35% to 95% (with no condensation)
50 M
1,000 VAC for 1 min between current-carrying parts and case
Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Destruction: 500 m/s
IEC 60529 IP67, in-house standards: oil-resistant
Pre-wired Models (Standard cable length: 2 m)
Approx. 45 g
Heat-resistant ABS
Instruction manual
10% max. of sensing distance at 23 C in the temperature range of 25 to 70 C
2.5% max. of sensing distance at rated voltage in the rated voltage 15% range
min. (at 500 VDC) between current-carrying parts and case
18
1 mm
Refer to the timing charts under I/O Circuit Diagrams on page 6 for details.
2
3 times each in X, Y, and Z directions
TL-W5MD@
TL-W
2

Related parts for TL-W3MC1