H5S-WB2 Omron Automation, H5S-WB2 Datasheet

no-image

H5S-WB2

Manufacturer Part Number
H5S-WB2
Description
Timer, Weekly, Flush Mounting, 2 Circuit Outputs, 100to240VAC Supply voltage
Manufacturer
Omron Automation
Type
Timerr
Datasheet

Specifications of H5S-WB2

Brand/series
H5S Series
Contact Form
SPST-NO
Dimensions
72mmL×53.2mmW×72mmH
Mounting Type
Flush
Number Of Outputs
2
Output Type
Digital/Relay
Primary Type
Controller
Standards
UL, cURus, CSA, CE
Voltage, Supply
100 to 240 VAC
Supply Voltage
100-240 VAC
Control Output
(2) — SPST-NO (15 A @ 250 VAC)
Lead Free Status / Rohs Status
RoHS Compliant part
Easier, More Convenient Time Switches, with
New 4-circuit Output and Yearly Models in
Addition to 2-circuit Weekly Models
• Independent Day Keys provide easier operation.
• Temporary holiday setting function makes it easy to turn OFF output
• Settings can be made even with the Time Switch turned OFF.
• Test mode enables easy program checking.
• Complies with EMC Directives, UL/CSA, and other safety standards.
• Includes summer time (DST) adjustment.
• Set value can be changed both upward and downward for speedier
• Integrated temperature compensation circuit helps keep accurate
• Includes time counter and total counter functions with alarm indicator.
• Bank function allows program switching by an external input. (See
• New 4-circuit output models with a compact, 72
Note: 1. Available only on yearly models.
Features
Easier and More Convenient to Use
Time Counter/Total Counter Functions (See note.)
This function makes it possible to monitor the total time that a load
has been applied, or the total number of operating cycles. It allows
the Time Switch to be used for managing maintenance.
for holidays and non-operating days.
Yearly models also offer automatic switching to DST.
setting.
time over a wide temperature range. (See note 1.)
(See note 2.)
note 3.)
added to the series.
Digital Time Switch
H5S
Independent Day Keys make setting easy.
Simple Setting
Convenient Functions
2. Available only on 2-circuit models.
3. Available only on weekly models.
With alarm indicator
Shows total lamp ON time
Up/down set value changing
for speedy setting.
Temporary holidays
(non-operating days)
are also easy to set.
Weekly models: Specify the day.
Yearly models: Specify the date.
72-mm DIN size
Time Adjustment Function (See note.)
The time can be set to 00 min 00 s by using an external input. The
times on multiple Time Switches can also be easily synchronized.
Note: Equipped on 2-circuit models.
Master
Digital Time Switch
Slave
Synchronized!
Slave
H5S
1

Related parts for H5S-WB2

H5S-WB2 Summary of contents

Page 1

... Shows total lamp ON time 72-mm DIN size Time Adjustment Function (See note.) The time can be set to 00 min using an external input. The times on multiple Time Switches can also be easily synchronized. Master Note: Equipped on 2-circuit models. Digital Time Switch Synchronized! Slave Slave H5S 1 ...

Page 2

... This ensures precise operation with minimal time lags all year round, regardless of temperature changes. Model Number Structure Model Number Legend Note: This model number legend includes combinations that are not available. Please check the “List of Models” for availability. H5S- @@@@@ - @ Control cycle W: Weekly ...

Page 3

... Weekly 2-circuit Models Yearly 2-circuit Models (H5S-W@2) (H5S-Y@2) Approx. 3 264 VAC 60 Hz Approx. 0 28.8 VDC 2 circuits Supply voltage Models 100 to 240 VAC H5S-WB2 24 VDC H5S-WB2D 100 to 240 VAC H5S-WFB2 24 VDC H5S-WFB2D 100 to 240 VAC H5S-YB2-X 24 VDC H5S-YB2D-X 100 to 240 VAC H5S-YFB2-X 24 VDC ...

Page 4

... EN 60730-2-7 (IEC 61000-4-4 power line 1 kV control line EN 60730-2-7 (IEC 61000-4-5 line to line (power line, output line line to ground (power line, output 0.5 kV line to line (input line line to ground (input line) EN 60730-2-7 (IEC 61000-4-11): 0.5-s cycle, 100% (rated voltage) Yearly 4-circuit Models (H5S-Y@4) ...

Page 5

... For details, refer to About Yearly Programs on page 18. Adds a yearly pulse-output operation to the weekly pulse-output program. For details, refer to About Yearly Programs on page 18. --- Yearly 4-circuit Models (H5S-Y@4) 48 steps/circuit (See note 2.) 12 steps/circuit (See note 3.) Yearly 4-circuit Models (H5S-Y@4) H5S Digital Time Switch 5 ...

Page 6

... Connections Terminal Arrangement H5S-@A@/-@B@ Flush Mounting Models (2-circuit models) Output 2 Input (Rear View Power Output 1 source H5S-@FA@/-@FB@ Surface Mounting Models (2-circuit models) Input Output (Front View Output 1 Power source Note: 1. The Time Switch output uses a no-voltage contact. An external power supply is required for applications in which a load is driven. ...

Page 7

... Use a tool such as long nose pliers to prepare the openings for pulling wires. Note: 1. The terminal screws are M3.5. 2. This illustration shows a 2-circuit model. The 4-circuit model has the same dimensions. H5S 10 Digital Time Switch 9.5 (53.2) Two terminal covers (included) ...