CA-110 SELCO, CA-110 Datasheet - Page 37

no-image

CA-110

Manufacturer Part Number
CA-110
Description
THERMOSTAT
Manufacturer
SELCO
Datasheet

Specifications of CA-110

Body Style
Disc
Brand/series
CA
Current Rating
15⁄10 A
Dielectric Rating
1500 VAC per 1 Minute
Dimensions
1.18 in. L × 0.570 in. W × 0.395 in. H
Function
Thermostat
Material, Housing
Phenolic
Mounting Style
Surface Mount
Mounting Type
Flat Surface
Output
NO
Primary Type
Thermostat
Range, Measurement
150 °C
Resistance, Insulation
100 Megohms or More
Standards
UL & cUL Listed and CSA Certified, VDE Approved, CE Marked
Technology
Thermal Conductive
Temperature, Operating, Maximum
160 °C
Temperature, Operating, Minimum
10 °C
Termination
Solder
Thermostat Type
Disc
Voltage, Supply
250 VAC
Lead Free Status / Rohs Status
RoHS Compliant part
KS Series - Temperature Control with S.P.S.T. Switch and Automatic Defrost
(714) 917-1333
I t i s t h e c u s t o m e r ’s s o l e r e s p o n s i b i l i t y t o s p e c i f y a n d d e t e r m i n e t h e s u i ta b i l i t y o f a pa r t i c u l a r
c o n t r o l o r c o m p o n e n t b a s e d o n t h e i r u n i q u e i n d i v i d u a l a p p l i c a t i o n s a n d r e q u i r e m e n ts
(800) 257-3526
C o l d C a p i l l a r y C o n t r o l s
www.selcoproducts.com
FAX (714) 917-1355
APPLICATIONS
Closing with rising temperature and possibility to manually
initiate a defrost function is achieved by pressing the defrost
pin (stroke approximate .157 (4mm)) until latching. By doing
this, the main switch is opened and locked until the defrost
temperature is reached at the sensing point of the capillary
which is normally fixed at the evaporator. After the defrost
temperature has been reached, the pressure pin returns to
its OFF position and the normal ON/OFF operation of the
temperature control is reset. Defrost function can be initiated
in any position of the dial shaft. If initiated in error, the defrost
function can be cancelled by turning the dial shaft to the OFF
position.
Terminal 3-4: Closes on temperature rise
Electrical ratings
Inductive load ratings
Temperature range
Adjustment range
Differential
Defrost temperature
Tolerance
Contact resistance
Insulation resistance
Dielectric strength
Approvals
Typical Electrical Wiring Diagram
3-4
Automotive air conditioning
Refrigerating/freezing devices
C
Main switch closes at temperature rise
Compressor
E-mail: sales@selcoproducts.com
SPECIFICATIONS
250V, 6 Amps, 50Hz
250V, 6FLA, 36LRA
120V, 10FLA, 40LRA
-40ºF to 104ºF (-40ºC to 40ºC)
4 to 14K
4 to 14K
Possible between 2ºC and 10ºC
Differential of defrost temperature to
WARM -IN minimum 4K
2.7ºF (1.5ºC) at calibration point
3.6ºF (2.0ºC) at non-calibration point
4.5ºF (2.5ºC) at defrost
<50m S
>100M S
AC 50/60Hz, 1500V/1 minute
UL, C-UL, VDE
Typical Function Chart