405A100F2X ATC Diversified Electronics, 405A100F2X Datasheet - Page 2

no-image

405A100F2X

Manufacturer Part Number
405A100F2X
Description
Relay; E-Mech; Timing; On Delay; SPDT; Cur-Rtg 10A; Ctrl-V 24-240/24AC/DC; Socket Mnt
Manufacturer
ATC Diversified Electronics
Datasheet

Specifications of 405A100F2X

Brand/series
405A Series
Contact Form
SPDT
Current, Rating
10 A
Function
Timing
Mounting Type
Socket
Number Of Pins
8
Power, Rating
240 VA
Relay Type
Electro Mechanical
Standards
cULus, CSA, CE
Termination
Plug-In
Timer Type
On Delay
Timing Range
1 or 10 sec.⁄min.⁄hrs.
Voltage, Control
240⁄24 VAC⁄VDC
Voltage, Rating
250⁄30 VAC⁄VDC
Timing Ranges
1 and 10 Sec, Min., Hours
Universal Power Supply
24-240 VAC and 24 VDC
Bellofram Precision Controls
Marsh Instruments
Options:
Accessories
8-Pin surface/DIN rail socket
Hold down for above socket
Panel mounting bracket
Plug-in socket kit (8-pin)
8-Pin panel socket w/rear facing terminals
BelGAS
8-pin On-Delay (with instantaneous contacts) Timing Mode
(low inrush current for short-circuit protected sensors)
Six dial-selected ranges (1 or 10 Sec/Min/Hrs)
Six dial-selected ranges (5 or 50 Sec/Min/Hrs) 500
Bellofram Diaphragm
Create Part Number >>>>> 405A
24 to 240 VAC (50/60 Hz) and 24 VDC F
8-Pin On-Delay Interval Timing Modes 2
Diversified Electronics
Voltage & Frequency
Range
0000-825-85-00
0407-025-13-00
0405-320-02-00
0319-261-45-00
Arrangement
600-3-0011
12 VDC
24 VDC
100
Standard
DigiTec Division
Features
Special K
N
E
1
X
Power
Requirements
Repeat
Accuracy
Minimum
Setting
Setting
Accuracy
Reset
Weight
Thermo-Couple Products
Universal power supply -
reverse polarity protected
Unit will accept power from
24 to 240 VAC, 50 or 60
Hz, (+10%, - 20%) 24
VDC (+20%, - 20%)
Varies as a function of
temperature. Any voltage
(constant temperature):
+/-0.5%*Any voltage (32°
F to 140° F): +/-1.5%
*Any voltage (0° F to 140°
F): +/-2.0%**Variation
from average actual time.
2% of range, with the
exception of 50 mSec on
the 1 second range
+/-5% of range
The TDR will reset properly
and not start timing when
subjected to an open start
switch leakage of 1.5 mA
or less. (Prox switch and
Triac drive applications)
5 oz. (140g)
AC
DC
b
a
c
Inrush - 1.5
Amps Power
required - 1.2
watts
Maximum
ripple
@100Hz - 5%
Current
required -
50mA
Power
required - 1.2
watts
“F” option -
Peak inrush
current = 2
AMPS @ 24
VDC
“N” option -
Peak inrush
current =
150 mA @ 24
VDC
0 to 20 mSec
power
interruption:
guaranteed
no reset.
20 to 65
mSec; it may
reset (40
mSec typical
reset).
Over 65
mSec
guaranteed
to reset.