366C400Q30PX ATC Diversified Electronics, 366C400Q30PX Datasheet - Page 3

no-image

366C400Q30PX

Manufacturer Part Number
366C400Q30PX
Description
Counter, Long-Ranger Computing
Manufacturer
ATC Diversified Electronics
Type
Counterr
Datasheet

Specifications of 366C400Q30PX

Connection Type
Screw
Cut Out, Panel
72×72 DIN
Dimensions
2.83" L × 2.83" H × 5.31" D
Display Digit Height
0.3 In.
Display Type
Digital
Function
Counter
Number Of Digits
3
Primary Type
Electronic
Range, Measurement
1 to 999, 10 to 9990, 100 to 99900 Counts
Voltage, Supply
120 VAC
\\\
MODELS
RANGE
REPEAT
ACCURACY
RESET TIME
COUNT INPUT
CHARACTERIS-
TICS
COUNT
CONTROL
MODES
DISPLAY
HOUSING
TERMINALS
SPECIFICATIONS
Display model only for operation at 120, 240
or 24 VAC; and 24 VDC. Unit counts on break
(i.e. when count input switch opens). Unit
operates in on delay mode only.
Switch-selectable ranges of 1 to 999, 10 to
9990, and 100 to 99900.
100% (+0 count on all ranges)
Clocked at 40 mSEC
72mm
dust and water-tight in panel mounted installa-
tions. NEMA 4 when mounted per installation
instructions.
16 screw terminals accessible at rear; integral
wiring diagram.
(max. bounce open time)
Min. pulse on time
Min. pulse off time
Min. Pulse on time
Min. Pulse off time
Bounce Immunity
Max. count rate
Max. count rate
Cycle Progress
Pulse Contact
Counting Bar
Repeat Cycle
Requirement
Single Cycle
2
Count-Out
DIN size; plug-in design; fully gasketed,
AC
DC
1000/MIN
(symmetrical input)
20 mSEC
30 mSEC
2000/MIN
(symmetrical input)
15 mSEC
15 mSEC
5 mSEC
10 mA at line voltage
interval or delayed
pulse (occurrence and
duration 50 mSEC
clocked)
3-digit display, 0.3
inch, high-intensity,
blue programmable
modes: DOWN &
STOP, DOWN & GO,
UP & STOP or UP &
GO.
at count-out
display; blinks on
when count switch is
closed, when pulse is
received
display; energized
Automatic Timing & Controls
COUNT INPUT
(terminal 15)
LOAD RELAY
POWER
REQUIREMENTS
TEMPERATURE
RATING
MOUNTING
ACCESSORIES
WEIGHT
Voltage Model
Operate Time 13 ms, max.
32 to 140°F (0 to 60°C)
NEMA 12 molded case (1 counter)
NEMA 1 steel case (2 counters)
NET: AC - 1 lb., 6oz. DC - 10 oz.
SHIPPING: AC - 2 lbs., DC - 1 lb., 4 oz.
Release Time 10 ms, max.
120 VAC
240 VAC
Standard
Optional
Number
24 VDC
Contact
24 VDC
24 VAC
24 VAC
Ratings
Model:
Model
Model
Model
120V
240V
Type
LIFE
Turn On 60V 3.5 mA (nom.)
Turn Off 30V 2.4 mA (nom.)
10 mA max. current at 120V
Turn On 120V 3.5 mA (nom.)
Turn Off 60V 2.4 mA (nom.)
10 mA max. current at 240V
Turn On 12V 9.5mA (nom.)
Turn Off 4V
30 mA max. current at 24V
Turn On 15 VDC 2.5 mA (nom.)
Turn Off 3 VDC .5 mA (nom.)
5 mA max. current at 24V
one instantaneous and one
delayed
DPDT, Form C
7A at 120, 240 or 24 VAC, 1/6
HP. 3A at 24 VDC, 1.5A at 48
VDC, 0.5A at 125 VDC.
100 million operations (no load)
95 to 132V, 50/60 Hz
inrush–0.3A
running–0.06A at 120 VAC
190 to 264V, 50/60 Hz
inrush–0.15A
running–0.03A at 240 VAC
19.2 - 26.4 VAC, 50 or 60 Hz
Inrush–1 A
Running–0.25 A at 24 VAC
19.2 - 26.4 VDC, 5% ripple
Running - .120 A at 24 VDC
hardware is provided for
front-of-panel mounting.
Surface-mounting brackets with
front-facing terminals
366B Series
3.8 mA (nom.)
133

Related parts for 366C400Q30PX