E3X-NA41 Omron Automation, E3X-NA41 Datasheet - Page 4

no-image

E3X-NA41

Manufacturer Part Number
E3X-NA41
Description
Amplifier; PNP; 12 to 24 VDC; 35 mA (Max.) (Standard); DIN Rail Track; Prewired
Manufacturer
Omron Automation
Datasheet

Specifications of E3X-NA41

Case Material
Polybutylene terephthalate (PBT)
Connection Type
Prewired
Cover Material
Polycarbonate
Current, Consumption
35 mA (Max.) (Standard)
Enclosure Rating
Polybutylene terephthalate (PBT)
Mounting Type
DIN Rail Track
Output Type
PNP
Response Time
200 μs (Max.) for Operation and Reset
Temperature, Ambient
-30 to +50 °C
Temperature, Storage
-25 to +70 °C
Voltage, Supply
12 to 24 VDC
Lead Free Status / Rohs Status
RoHS Compliant part

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
E3X-NA41
Manufacturer:
AVAGO
Quantity:
11 130
E3X-NA
Nomenclature
I
Lock Button
I
Indicators
In addition to an operation indicator (orange), the E3X-NA also has
incident level indicators (4 green and 1 red). Use these indicators for
optical axis adjustments and maintenance.
Note:
4
Status of indicators
(in L/ON mode)
Operation indicator Incident level indicators
Amplifier Units
LED Bar Display
Operation Indicator
The indicator farthest to the right will be lit even if the incident
level is 0.
Incident level Indicators
Sensitivity Indicator
Not lit
8-Turn Sensitivity Adjuster
Lit
(See note.)
Timer Switch
OFF: Timer function is OFF.
ON: Timer function is ON.
Operation
indicator
(in L/ON
mode)
Not lit
Not lit
Not lit or lit
Lit
Lit
Operation Mode Selector
Use to switch between
Light ON and Dark ON modes.
Incident level
Approx.
80% max. of
operating level
Approx. 80%
to 90% of
operating level
Approx. 90%
to 110% of
operating level
Approx. 110%
to 120% of
operating level
Approx.
120% min. of
operating level
E3X-NA