H7ET-N-B Omron Automation, H7ET-N-B Datasheet - Page 4

no-image

H7ET-N-B

Manufacturer Part Number
H7ET-N-B
Description
Totalizer; Time; 24 VDC (Only for backlight); Digital; LCD; 7; 0.0 to 999999.9
Manufacturer
Omron Automation
Type
Timerr
Datasheet

Specifications of H7ET-N-B

Color, Case
Black
Connection Type
Screw
Counter Type
Time
Cut Out, Panel
45×22.2 mm
Dielectric Rating
1,000 VAC, 50⁄60 Hz for 1
Digit Height
8.6
Dimensions
48.5mmL×48mmW×35mmH
Display Digit Height
8.6 mm
Display Range
0.0 to 999999.9
Display Type
LCD
Function
Timer
Input Type
Count
Memory Type
Lithium Battery
Mounting Type
Panel
Number Of Digits
8
Output Type
Digital
Primary Type
Electronic
Range, Measurement
0 to 999999.9 hrs.
Resistance, Insulation
100 M≠ (Min.) @ 500 VDC
Signal, Input
No Voltage
Standards
UL Recognized, CSA Certified, CE Marked
Temperature, Operating, Range
-10 to +55 °C
Terminal Type
Screw Terminal
Termination
Screw Terminal
Voltage, Supply
24 VDC
Weight
65 g
4-digit Tachometer
1000 RPS (1 Pulse/Rev.), 1000 RPM (60 Pulse/Rev.)
Lead Free Status / Rohs Status
RoHS Compliant part
■ Characteristics
Note: Weight includes waterproof packing and flush mounting bracket.
■ Reference Value
Time accuracy
Insulation resistance
Dielectric strength
Impulse withstand
voltage
Noise immunity
Static immunity
Vibration resistance
Shock resistance
EMC
Degree of protection
Weight (see note)
Battery life
Item
Item
10 years min. with continuous input at
25°C (lithium battery)
±100 ppm (25°C)
100 MΩ min. (at 500 VDC) between
current-carrying metal parts and ex-
posed non-current-carrying metal
parts, and between the backlight pow-
er supply and timer input terminals/re-
set terminals for backlight models
1,000 VAC, 50/60 Hz for 1 min between
current-carrying metal parts and ex-
posed non-current-carrying metal
parts and between the backlight power
supply and timer input terminals/reset
terminals for backlight models
4.5 kV between current-carrying termi-
nal and exposed non-current-carrying
metal parts
Square-wave noise generated by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise)
±600 V (Between timer input terminals/
Between reset terminals)
±480 V (Between the backlight power
supply terminals for backlight models)
±8 kV (malfunction)
Malfunction: 0.15-mm single amplitude at 10 to 55 Hz for 10 min each in 3 directions
Destruction: 0.375-mm single amplitude at 10 to 55 Hz for 2 hrs each in 3 directions
Malfunction: 200 m/s
Destruction: 300 m/s
(EMI)
Emission Enclosure:
(EMS)
Immunity ESD:
Immunity RF-interference from AM Radio Waves:
Immunity RF-interference from Pulse-modulated Radio Waves:
Immunity Conducted Disturbance: EN61000-4-6: 10 V (0.15 to 80 MHz) (level 3)
Immunity Burst:
Front panel:
Terminal block: IP20
No-backlight model: Approx. 60 g
Backlight model: Approx. 65 g
H7ET-NV@-H@
H7ET-NV@-@
Value
IP66, NEMA4 with waterproof packing
2
2
3 times each in 6 directions
3 times each in 6 directions
EN61326
EN55011 Group 1 class B
EN61326
EN61000-4-2: 4 kV contact discharge (level 2)
EN61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3)
EN61000-4-3: 10 V/m (900 MHz ± 5 MHz) (level 3)
EN61000-4-4: 2 kV power line (level 3)
The battery life is calculated according to the conditions in the left column and
therefore is not a guaranteed value. Use these value as reference for mainte-
nance or replacement.
100 MΩ min. (at 500 VDC) between
current-carrying metal parts and ex-
posed non-current-carrying metal
parts and between timer input termi-
nals and reset terminals
3,700 VAC, 50/60 Hz for 1 min between
timer input terminals and exposed non-
current-carrying metal parts
2,200 VAC, 50/60 Hz for 1 min between
reset terminals and exposed non-cur-
rent-carrying metal parts and between
timer input terminals and reset termi-
nals
4.5 kV between current-carrying termi-
nal and exposed non-current-carrying
metal parts
3 kV between timer input terminals and
reset terminals
±1.5 kV (Between timer input termi-
nals)
±500 V (Between reset terminals)
Approx. 60 g
H7ET-NFV@-@
8 kV air discharge (level 3)
2 kV I/O signal line (level 4)
Note
100 MΩ min. (at 500 VDC) between
current-carrying metal parts and ex-
posed non-current-carrying metal
parts
1,000 VAC, 50/60 Hz for 1 min between
current-carrying metal parts and ex-
posed non-current-carrying metal
parts
4.5 kV between current-carrying termi-
nal and exposed non-current-carrying
metal parts
±500 V (Between timer input terminals/
Between reset terminals)
Approx. 60 g
H7ET-N@-@
New H7ET
11

Related parts for H7ET-N-B