TDRSOXB-120 Magnecraft/Schneider Electric, TDRSOXB-120 Datasheet - Page 2

no-image

TDRSOXB-120

Manufacturer Part Number
TDRSOXB-120
Description
Relay; E-Mech; Timing; On Delay; DPDT; Cur-Rtg 12A; Ctrl-V 120AC/DC; Blade; 8 Pin
Manufacturer
Magnecraft/Schneider Electric
Datasheet

Specifications of TDRSOXB-120

Brand/series
TDRSOX Series
Contact Form
DPDT
Current, Rating
12 A
Display Type
LED
Function
Timing
Material, Contact
Silver Alloy
Number Of Pins
8
Relay Type
Electro Mechanical
Standards
UL, CE
Temperature, Operating, Maximum
55 °C
Temperature, Operating, Minimum
-20 °C
Termination
Blade
Timer Type
On Delay
Timing Range
0.1 sec. to 10 hrs.
Voltage, Control
120 VAC⁄VDC
Voltage, Rating
240⁄30 VAC⁄VDC
Tdrsox
On Delay, Interval
Tdrsrx
Off Delay, Retriggerable One-ShotFeatures
Dual Function
On Delay/Interval, Off Delay/Retriggerable One Shot
Indicator Leds
Green Shows Power ON, Red Shows Output Relay Energized
Compact Size
36 mm Wide to Optimize DIN Rail Space
Accepts Flange Adapters
Panel Mount or DIN Mount with Terminals Exposed
Removable Knob
Prevent Tampering, Remove Knob to Expose Recessed Screwdriver Slot
Protection
IP40
Lead Free Status / Rohs Status
RoHS Compliant part
Function
A.
ON DELAY
Power On
B.
REPEAT CYCLE
Starting Off
C.
INTERVAL
Power On
D.
OFF DELAY
S Break
E.
RETRIGGERABLE
ONE SHOT
F.
REPEAT CYCLE
Starting On
G.
PULSE
GENERATOR
H.
ONE SHOT
I.
ON/OFF DELAY
S Make/Break
J.
MEMORY LATCH
S Make
M ag n e cr a f t S olu t i o n G ui de 10 5A
U = Input Voltage
FUNCTION DEFINITION TABLE
Operation
When the input voltage U is applied, timing delay t begins. Relay contacts R
change state after time delay is complete. Contacts R return to their shelf state
when input voltage U is removed. Trigger switch is not used in this function.
When input voltage U is applied, time delay t begins. When time delay t is
complete, relay contacts R change state for time delay t. This cycle will repeat
until input voltage U is removed. Trigger switch is not used in this function.
When input voltage U is applied, relay contacts R change state immediately
and timing cycle begins. When time delay is complete, contacts return to shelf
state. When input voltage U is removed, contacts will also return to their shelf
state. Trigger switch is not used in this function.
Input voltage U must be applied continuously. When trigger switch S is closed,
relay contacts R change state. When trigger switch S is opened, delay t begins.
When delay t is complete, contacts R return to their shelf state. If trigger switch
S is closed before time delay t is complete, then time is reset. When trigger
switch S is opened, the delay begins again, and relay contacts R remain in
their energized state. If input voltage U is removed, relay contacts R return to
their shelf state.
Upon application of input voltage U, the relay is ready to accept trigger signal S.
Upon application of the trigger signal S, the relay contacts R transfer and the
preset time t begins. At the end of the preset time t, the relay contacts R return to
their normal condition unless the trigger switch S is opened and closed prior to
time out t (before preset time elapses). Continuous cycling of the trigger switch S
at a rate faster than the preset time will cause the relay contacts R to remain
closed. If input voltage U is removed, relay contacts R return to their shelf state.
When input voltage U is applied, relay contacts R change state immediately
and time delay t begins. When time delay t is complete, contacts return to
their shelf state for time delay t. This cycle will repeat until input voltage U is
removed. Trigger switch is not used in this function.
Upon application of input voltage U, a single output pulse of 0.5 seconds is
delivered to relay after time delay t. Power must be removed and reapplied to
repeat pulse. Trigger switch is not used in this function.
Upon application of input voltage U, the relay is ready to accept trigger signal
S. Upon application of the trigger signal S, the relay contacts R transfer and
the preset time t begins. During time-out, the trigger signal S is ignored. The
relay resets by applying the trigger switch S when the relay is not energized.
Input voltage U must be applied continuously. When trigger switch S is closed,
time delay t begins. When time delay t is complete, relay contacts R change
state and remain transferred until trigger switch S is opened. If input voltage U
is removed, relay contacts R return to their shelf state.
Input voltage U must be applied continuously. Output changes state with every
trigger switch S closure. If input voltage U is removed, relay contacts R return to
their shelf state.
S = Trigger Switch
R = Relay Contacts
t = Time Delay
U
U
R
U
R
U
R
U
S
R
U
S
R
R
U
R
U
S
R
U
S
R
U
S
R
Timing Chart
close
open
close
open
close
open
close
open
close
open
on
off
on
off
on
off
on
off
on
off
on
off
on
off
on
off
on
off
t
t
t
t
t
t
t
t
Pulse
t
t
t
t
t
t
t
t
t
t
t
t
t
t
Pulse
t
t
t
t
t
5/3

Related parts for TDRSOXB-120