38XRA Amprobe, 38XRA Datasheet - Page 2

no-image

38XRA

Manufacturer Part Number
38XRA
Description
Multimeter, Digital; 1000 mV, 10, 100, 1000 VDC Voltage, Range, DC; RS-232; LC
Manufacturer
Amprobe
Type
DMMr
Datasheet

Specifications of 38XRA

Battery Type
9V
Capacitance
400 uF
Capacitance Range
40 nF, 400 nF, 4 μF, 400 μF
Current, Range
100 μA, 1000 μA, 10 mA, 100 mA, 400 mA, 10 A
Dimensions
7.8 × 3.55 × 2.4 mm
Display Type
LCD
Frequency Range
100 Hz, 1000 Hz, 10 kHz, 100 kHz, 1000 kHz, 10 MHz
Resistance, Range
1000 Ω, 10 kΩ, 100 kΩ, 1000 kΩ, 10 MΩ, 40 MΩ
Temperature, Operating
1832°F
Voltage, Range, Ac
1000 mV, 10 V, 100 V, 750 V
Voltage, Range, Dc
1000 mV, 10 V, 100 V, 1000 V
Weight
400 g
38XR-A Digital Multimeter
General Specifications
Specifications
DC Voltage
AC Voltage (45 Hz to 2 kHz) True RMS
AC coupled True RMS specified from 5% to 100 % of range
AC + DC Voltage (45 Hz to 2 kHz)
DC coupled True RMS specified from 5 % to 100 % of range
DC Current
AC Current (True RMS) ( AC + DC) (45 Hz – 1kHz)
AC coupled True RMS specified from 5 % to 100 % of range
AC + DC Accuracy
AC + DC: AC coupled True RMS specified from 10 % to 100 % of range
Resistance
Amprobe® Test Tools
Autoranging
Display:
Display Update Rate:
Power Battery:
Battery Life:
Storage Temperature:
Temperature Coefficient:
Altitude:
Dimensions:
Weight:
Function
Ranges
Resolution
Ranges
Accuracy
Ranges
Accuracy
Resolution
Ranges
Resolution
Ranges
Accuracy
Resolution
Ranges
Accuracy
Resolution
(23 °C ± 5 °C, <75 % R.H. non-condensing)
4-3/4 digit LCD, 10,000 counts with 41-segment analog bar graph
2/sec, nominal
9 V NEDA 1604, JIS 006P, IEC 6F22
150 hrs typical (alkaline) frequent use of backlight will decrease battery life; Operating Temperature: 0
°C to 45 °C at < 70% R.H.
-20 °C to 60 °C, 0 to 80 % R.H. with battery removed from meter
0.1 x (specified accuracy) per °C (0 °C to 18 °C , 28 °C to 45 °C)
2000 m (6562 ft)
196mm x 96mm x 60 mm (7.8” x 3.55” x 2.4”)
400 gr (1 lb) without holster, including battery
Range
1000 mV, 10 V, 100 V, 1000 V
100 μV
1000 mV, 10 V, 100 V, 750 V
750 V range:
All other ranges, 45 to 500 Hz:
All other ranges, 500 to 2 kHz:
1000 mV, 10 V, 100 V, 750 V
750 V range: 45 to 1 kHz:
All other ranges, 45 to 500 Hz:
All other ranges, 500 to 2 kHz:
100 μV
100 μA, 1000 uA, 10 mA, 100 mA, 400 mA, 10 A
Accuracy 100 μA range:
1000 uA to 400 mA ranges:
10 A range:
0.01 μA
100 μA, 1000 μA, 10 mA, 100 mA, 400 mA, 10 A
100 μA to 100 mA ranges:
400 mA range:
10 A range:
0.01 μA
100 μA to 400 mA ranges:
10 A range:
1000 W, 10 kW, 100 kW, 1000 kW, 10 MW, 40 MW
1000 W to 1000 kW ranges:
10 MW range:
40 MW range:
100 mW
± (0.25 % rdg + 5 dgt)
45 to 1 kHz: ± (2.0 % rdg + 10 dgts)
± (1.2 % rdg + 10 dgts)
± (2.0 % rdg + 10 dgts)
± (2.5 % rdg + 10 dgts)
± (1.5 % rdg + 10 dgts)
± (2.5 % rdg + 10 dgts)
± (0.5 % rdg + 10 dgt)
± (0.5 % rdg + 5 dgts)
±(1.5 % rdg + 10 dgt)
± (1.5 % rdg + 20 dgts)
± (2.0 % rdg + 10 dgts)
± (2.5 % rdg + 20 dgts)
± (2.0 % rdg + 20 dgts)
± (3.0 % rdg + 20 dgts)
± (0.5 % rdg + 8 dgts)
± (1.0 % rdg + 10 dgts)
± (2.0 % rdg + 10 dgts)
Accuracy
www.Amprobe.com
Data Sheet