PC-50 Pacific Scientific OECO, PC-50 Datasheet

no-image

PC-50

Manufacturer Part Number
PC-50
Description
Sensor, Current; 50A Pri:20 to 100Hz; 4 to 20mA (DC); +/-0.5%; 0.73In.Dia.; UL Listed
Manufacturer
Pacific Scientific OECO
Type
Inductiver
Datasheet

Specifications of PC-50

Accuracy
± 0.5 %
Brand/series
PC
Current, Primary
50 A (RMS)
Current, Secondary
4 to 20 mA (DC)
Current, Switching
20 mA
Diameter, Inside
0.73 in.
Frequency Response
20 to100 Hz
Function
Current
Height
4.22 in.
Length
3.5 in.
Mounting Type
Panel
Output
Current
Primary Type
Current
Range, Measurement
50 A
Standards
UL Listed
Technology
Inductive
Voltage, Supply
40 VDC
Width
0.071 in.
Lead Free Status / Rohs Status
RoHS Compliant part

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PC-508
Manufacturer:
ST
Quantity:
2
Part Number:
PC-508A
Manufacturer:
OSRAM
Quantity:
12 000
Part Number:
PC-508B
Manufacturer:
SHARP
Quantity:
116
Model PC and PCS
AC Current Sensors
Description
The PC/PCS Series current sensors accurately measure
sinusoidal AC current and provide a 4-20 mA DC output
proportional to the RMS value. They are loop powered
requiring only a two wire connection. The PCS-50 and
PCS-200 clamp over existing wiring for easy installation.
Features
• UL Listed • Loop Powered • Range Selected on Sensor
• Only Requires Two Wire Connection • Features Split Core for Easy Installation
Electrical Specifications
Current Range (1) .............. A AC rm s
Output (2) ......................... mA DC
Frequency Range ................ Hz
Suppl y Voltage (3) .............. VDC
Accuracy ........................... +% Full Scale (FS)
Repeatability ...................... +% FS
Linearity ............................ +% FS
Response time (Max.) ......... m s
Ripple and Noise (Max.) ...... mV Peak to Peak
Output Current Limit (4) ..... m A
Internal Protection ..............
Dielectric test (6) ................ kV
General Information
Operating Temperature (5) ...
Aperture Opening ............... inches (mm)
Weight ............................. grams
Mounting ..........................
Package ...........................
Notes:
1. Refer to Table 1 for choice of current ranges.
2. Refer to Table 2
3. Minimum voltage is 5 volts (for the sensor) plus voltage dropped across total load resistance when sensor is at 20 mA. Example: 20
4. Sensor self-limits output current to 40 mA maximum.
5. The UL approval is for an operating temperature range of -10
6. The dielectric test consists of 5.0 kVac 60 Hz for one minute between a bare 0.8 inch diameter conductor (located concentrically
through the aperture) and the output of the sensor.
mA will drop 16 volts across 800 ohms total load resistance. 16 volts plus 5 volts equals 21 volts minimum requirement.
O
Units
C
o
C to +40
Reverse voltage protection, High over-current capability
ABS plastic case meets UL f lammability rating 94V - 0
0.73 (18.5)
PC-50
o
C.
0.1
92
50
Panel mount via two #6 screws
PC-200
20 to 100
0.73 (18.5)
-20 to +50
40 Max.
4 to 20
5 to 40
0.5
0.1
0.1
300
200
92
5
8
Current Sensors
PCS-50
0.85 (21.6)
0.3
50
121
PCS-200
0.85 (21.6)
200
0.3
121

Related parts for PC-50

PC-50 Summary of contents

Page 1

... Sensor self-limits output current maximum. 5. The UL approval is for an operating temperature range of -10 6. The dielectric test consists of 5.0 kVac 60 Hz for one minute between a bare 0.8 inch diameter conductor (located concentrically through the aperture) and the output of the sensor. Current Sensors PC-50 PC-200 PCS-50 50 200 ...

Page 2

... PC-50 and PCS-50 .190 DIA. (4.83) (2-PLCS.) .590 (14.99) Connection Schematic .245 MAX. (6.22) PC /PCS Sensor 1.752 (44.50) .510 (12.95) Connection to sensor is made via two 6-32 screw terminals Jumper Maximum Currents Continuous None 80 Amps Mid 110 Amps High 175 Amps ...