LR2K0308 TELEMECANIQUE, LR2K0308 Datasheet - Page 34

no-image

LR2K0308

Manufacturer Part Number
LR2K0308
Description
RELAY, OVERLOAD, MINIATURE, CLASS 10, 1.8 TO 2.6 AMPS
Manufacturer
TELEMECANIQUE
Type
Overloadr
Datasheet

Specifications of LR2K0308

Contact Rating
1.8 to 2.6 A
Current, Rating Max
2.6
Function
Overload
Number Of Circuits
1
Number Of Poles
3
Primary Type
Contactor
Relay Type
Electro Mechanical
Reset Type
Manual or Auto
Standard Tripping Time
Between 4 and 10 Sec. for 7.2 Times the Setting Current
Dimensions (l × W × H, Mm)
58 × 45 × 65
Starters Accessories
18-34
GVAD0101
GVAU116
GVAN11
GVAE11
Table 18.128: Voltage Trips
Table 18.129: Auxiliary Contact Blocks
Table 18.130: Voltage Trips–Technical Data (GV2AU, GV2AS)
Table 18.131: GV3P Accessories
Instantaneous auxiliary contacts
a
instantaneous auxiliary contact
b
c
d
e
f
g
h
Short circuit signaling contact
GV2 & GV3P
Description
Voltage trips
Fault signaling contact +
For use with up to 4 padlocks (not supplied)
To order an under voltage trip: replace the bullet (
GVAS025.
Mounting of a GVAE contact block or a GV2AK00 visible isolation block on GV2P.
Choice of N.C. or N.O. contact operation, depending on which way the reversible block is mounted.
The GVAD is always mounted next to the starter.
For spring terminals add 3 to the catalog number. Example: GVAE113
One trip or one fault signaling can be fitted per GV3.
Cannot be used with GV2GH7 insulator.
From the loss of voltage at the trip terminals to the opening of the starter contacts.
(Only one cover required on supply side)
Cover “Larger Spacing” UL 508 type E
Model
GVAU
GVAS
GV2 + GV3P
GV2 + GV3P
GV2 + GV3P
Description
(Two covers required per starter)
Set of 3-pole 115 A busbars
Set of 3-pole 115 A busbars
(tap-offs: 2, pitch: 64 mm)
(tap-offs: 3, pitch: 64 mm)
Ø 6 mm shank maximum
Padlocking device
Description
IP 20 cover
1 block right side only)
Characteristics
Undervoltage or
(external mount,
TeSys
Shunt trip
14 VA / 10.5 W
12 VA / 8 W
Inrush
Left Hand Sided
Left Hand Side
Left Hand Side
®
Only one trip or fault signaling contact can be installed per GV2/GV3 device.
Mounting
CP10
Location
Frontbg
GV2 and GV3 Manual Starters and Protectors
New!
I11
100–110 V
110–115 V
120–127 V
200–220 V
220–240 V
380–400 V
415–440 V
Voltage
127 V
200 V
415 V
440 V
480 V
500 V
600 V
24 V
48 V
Max. No. of
) with a U, example: GVAU025. To order a shunt trip: replace the bullet (
Discount
Schedule
3.5 VA / 1.1 W
Blocks
5 VA / 1.6 W
Sealed
1
2
1
1
Rated Voltage–660 Vac
N.O. (fault) + N.O.
N.O. (fault) + N.C.
N.C. (fault) + N.O.
N.C. (fault) + N.C.
Contact Type
N.O. or N.C.c
For GV3P
GV3P
GV3P
GV3P
GV3P
GV3P
GV3P
N.O. + N.C.
N.O. + N.O.
N.O. + N.C.
N.O. + N.O.
Frequency
SPDT
50/60 Hz
50 Hz
60 Hz
50 Hz
60 Hz
50 Hz
60 Hz
50 Hz
60 Hz
50 Hz
60 Hz
50 Hz
60 Hz
50 Hz
60 Hz
50 Hz
60 Hz
60 Hz
60 Hz
50 Hz
60 Hz
•••
••
••
••
••
••
Refer to Catalog 2502CT0001
Pick-Up Voltage
0.8 to 1.1
0.7 to 1.1
Sold in lots of
10
1
1
1
1
1
1
1
1
1
Drop-Out Voltage
Catalog Numbera
0.35 to 0.7
0.2 to 0.75
GVA
GVA
GVA
GVA
GVA
GVA
GVA
GVA
GVA
GVA
GVA
GVA
GVA
GVA
GVA
GVA
GVA
GVA
GVA
GVA
Catalog Number
LAD96570
GV3G264
GV3G364
GV3G66
GV2V03
025
026
055
056
107
115
116
125
115
207
207
225
226
385
386
415
416
385
415
505
Catalog Number
GVAD1010
GVAD1001
GVAD0110
GVAD0101
GVAE11e
GVAE20e
GVAN11e
GVAN20e
GVAM11
GVAE1
www.schneider-electric.us
© 2009 Schneider Electric
) with an S, example:
Operating Timeh
All Rights Reserved
10 to 15 ms
10 to 15 ms
$ Price
$ Price
$ Price
25.00
45.00
18.00
12.00
15.00
81.00
21.80
35.70
35.70
35.70
35.70
54.00
54.00
54.00
54.00
35.70