SR104P02 Sti (Scientific Technologies, Inc.), SR104P02 Datasheet
SR104P02
Specifications of SR104P02
Related parts for SR104P02
SR104P02 Summary of contents
Page 1
SR104P H SR104P Two-Hand Control Safety Monitoring Relay Power requirements—the ■ SR104P will accept 24 VAC/DC and 115 VAC Inputs—controls and monitors ■ two-hand control switches to ensure that both switches are operated within 0.5 seconds of each other Outputs—the ...
Page 2
Application ■ 24VAC/DC, 115 VAC SWITCH 1 S11 S12 S13 (control logic, relay logic, time circuit) channel 1 Sr104P K1 The SR104P only allows machine operation if both buttons are operated at the same time. Operating ...
Page 3
SR104P Block Diagram ■ S11 S12 Dimensions — mm/in. ■ Sr104P 114 4.5 35 Din rAil mOUnting 1.38 S13 S23 X1 S21 S22 K1 K2 control logic (control logic, relay logic, time circuit) channel ...
Page 4
... EN 60204-1, EN 574 Cat. IIIC, EN 954-1, VDE 0113-1 CE marked for all applicable directives, UL and C-UL, BG Cat. 4 per EN954-1 (SR104 internal operation) inputs pole (1 N N/O) hand switches pole (1 N N/O) hand switches SR104P Sr104P02 115 VAC Outputs Part no. 2 N/O 44510-1041 2 N/O ...