1110-F112-P1M1-1A E-T-A Circuit Protection and Control, 1110-F112-P1M1-1A Datasheet

no-image

1110-F112-P1M1-1A

Manufacturer Part Number
1110-F112-P1M1-1A
Description
Circuit Breaker; Therm; Push; Cur-Rtg 1A; Snap-In Panel; 1 Pole; Vol-Rtg 250/28VAC/VDC
Manufacturer
E-T-A Circuit Protection and Control
Type
Thermalr
Datasheet

Specifications of 1110-F112-P1M1-1A

Actuator Type
Push
Application
Motors, transformers, solenoids, extra low voltage systems, household and office machines, instrumentation, marine applications, mobile homes
Brand/series
1110 Series
Characteristic
Medium Delay
Color, Button
Black
Current, Rating
1 A
Dielectric Strength
3000
Dimensions
0.748"Lx0.748"Wx2.01"H
Indicator
White Indicator Ring
Mounting Hole Size
0.63x0.531 "
Mounting Type
Snap-In Panel
Number Of Poles
1
Resistance, Insulation
100 Megohms (Min.)
Standards
UL Listed, CSA Certified
Temperature, Operating, Maximum
60 °C
Temperature, Operating, Minimum
-20 °C
Termination
Blade
Voltage, Rating
250/28 VAC/VDC
Lead Free Status / Rohs Status
RoHS Compliant part
Type: 1110
Dimensions
Internal connection diagrams
Single pole switch/thermal circuit breaker (S-type TO CBE to EN 60934)
with tease-free, trip-free, snap action mechanism. Designed for snap-in
panel mounting utilising round hole or industry standard fuse-holder cut-
out dimensions. Featuring an ergonomically styled two colour actuator
with indicator band clearly showing the tripped/OFF position.
Approved to CBE standard EN 60934 (IEC 60934).
Voltage rating:
Current ratings:
from 0.05 A to 16 A
Number of poles:
single pole
Mounting method:
flange
Terminal design:
blade terminals
Actuation:
push button
Auxiliary contacts:
without auxiliary contacts
Water splash protection:
with water splash protection
without water splash protection
Illumination:
without illumination
Typical life:
0.05...10 A: 10,000 operations at 1 x I
12...16 A: 6,000 operations at 1 x I
Interrupting capacity I
AC 250 V:
0.05...16 A: 8 x I
DC 28 V:
0.05...6 A: 10 x I
7...10 A: 200 A
12...16 A: 400 A
Approvals:
VDE, CSA, UL
AC 250 V
DC 28 V
UL/CSA: DC 50 V
N
N
cn
:
N
, inductive
N
, inductive

Related parts for 1110-F112-P1M1-1A

1110-F112-P1M1-1A Summary of contents

Page 1

... Type: 1110 Single pole switch/thermal circuit breaker (S-type TO CBE to EN 60934) with tease-free, trip-free, snap action mechanism. Designed for snap-in panel mounting utilising round hole or industry standard fuse-holder cut- out dimensions. Featuring an ergonomically styled two colour actuator with indicator band clearly showing the tripped/OFF position. ...

Page 2

... Other indicator ring colours are available to special order Terminal design P1 blade terminals A6.3-0.8 (QC .250) Characteristic curve M1 medium delay Current ratings 0.05...16A 1110 - 0. ordering example Standard current ratings and typical internal resistance values Current Internal Current rating (A) resistance (Ω) rating (A) 0.05 ...

Page 3

... Thermal Overcurrent Circuit Breaker 1110-... Dimensions 1110-F1.. / -F2.. When installing the circuit breaker apply pressure on bezel only. 19 .748 10 1 .394 12.1 .476 15.6 .61 blade terminals DIN 46244-A6.3-0.8 (QC .250) Panel cut out 1110-F1..-P.M1-...A +0.2 ±0.05 - 0.4 ±.002 +.008 - .016 installation side ± ...