LY2-0-DC12 Omron Automation, LY2-0-DC12 Datasheet - Page 5

no-image

LY2-0-DC12

Manufacturer Part Number
LY2-0-DC12
Description
RELAY; E-MECH; GEN PURP; DPDT; CUR-RTG 10A; CTRL-V 12DC; VOL-RTG 250/125AC/DC; 8 PIN
Manufacturer
Omron Automation
Datasheet

Specifications of LY2-0-DC12

Lead Free Status / Rohs Status
RoHS Compliant part

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LY2-0-DC12V
Quantity:
12 000
■ Characteristics
Note: Data shown are of initial value.
■ Characteristic Data
Maximum switching capacity
LY1
Electrical service life
LY1
Contact resistance
Operate time
Release time
Operating frequency
Insulation resistance
Dielectric strength
Vibration
Shock
Ambient temperature
Humidity
Service Life
Weight
Rated operating voltage (V)
Switching current (A)
Mechanically
Under rated load
Mechanical durability
Malfunction durability
Mechanical durability
Malfunction durability
Operating
Mechanically
Electrically
LY2
LY2
Rated operating voltage (V)
Switching current (A)
50 mΩ max.
25 ms max.
25 ms max.
18,000 operations/hour
1,800 operations/hour
100 MΩ min. (at 500 VDC)
2,000 VAC, 50/60 Hz for 1 minute
1,000 VAC, 50/60 Hz for 1 minute between contacts of same polarity
10 to 55 Hz, 1.00 mm (0.04 in) double amplitude
10 to 55 Hz, 1.00 mm (0.04 in) double amplitude
1,000 m/s
200 m/s
-40° to 70°C (-40° to 158°F) (over 4A carry currents 55°C max.)
35 to 85% RH
AC: 50 million operations min. (at operating frequency of 18,000 operations/hour)
DC: 100 million operations min. (at operating frequency of 18,000 operations/hour)
See “Characteristic Data”
SPDT, DPDT: Approx. 40 g (1.41 oz), 3PDT: Approx. 50 g (1.76 oz)
4PDT: Approx. 70 g (2.47 oz)
2
(approx. 20 G)
2
(approx. 100 G)
LY3, LY4
LY3, LY4
Rated operating voltage (V)
Switching current (A)
General Purpose Relay
LY2Z
LY2Z
Rated operating voltage (V)
Switching current (A)
LY
5

Related parts for LY2-0-DC12