U1731B Agilent Technologies Test Equipment, U1731B Datasheet

no-image

U1731B

Manufacturer Part Number
U1731B
Description
Orange Handheld LCR Meter
Manufacturer
Agilent Technologies Test Equipment
Type
LCR Meterr
Datasheet

Specifications of U1731B

Backlight
Yes
Capacitance Accuracy
Up to 0.7% + 5 lsd
Capacitance Range
0.1 pF to 199.99 mF
Color, Body
Orange
Display Type
Dual-Display LCD
Includes
Quick Start Guide, Alligator clip leads, 9 V Alkaline battery, Certifi cation of Calibration (CoC)
Interface
IR to USB
Resistance Range
0.001 Ω to 9.999 MΩ
Resolution
20,000 Counts
Agilent U1700 Series handheld LCR meters
expand Agilent’s portfolio of handheld tools
into electronics assembly and passive
components troubleshooting. Better yet, these
handheld models extends the tradition of
Agilent’s industry-leading benchtop units to
more affordable and portable forms. Agilent’s
latest handheld LCR meters in all-new orange
offer capabilities and functionalities equivalent
to the A models.
Features
(for U1732A/U1732B)
Wide LCR ranges with 2 to 4 selectable
test frequencies
(for U1732A/U1732B), dissipation factor
and quality factor
(20% with U1732A/U1732B)
recordings
IR-to-USB cable
20,000 counts resolution
Dual display with backlight
Auto-calculation of phase angle
Tolerance mode: 1%, 5% and 10%
Relative mode
Hold and Min/Max/Average
Data logging to PC with optional
Agilent U1700 Series Handheld LCR Meters
Data Sheet
Test passive components conveniently, affordably and reliably
with the Agilent U1700 Series LCR meters
— extending the tradition of industry-leading benchtop units
No waiting for quick, basic LCR
tests
Sharing a bench LCR meter is practical, but
isn’t always convenient. With Agilent’s new
line of handheld LCR meters, you can perform
quick, basic LCR measurements at your
convenience. Now that they’re available at a
lower price point compared to traditional
benchtop units, everyone on your team can
be equipped for passive-component testing—
on the bench or on the go—without the wait.
Figure 1: Automate the recording of continuous
readings when you hook the
U1731A/U1731B/U1732A/U1732B to a PC
Uncompromised quality and
reliability
The handheld LCR meters are housed in robust
overmold and tested to stringent industrial
standards. Each LCR meter is also sealed with
a three-year warranty and the assurance that
you can test your components with confidence.

U1731B Summary of contents

Page 1

... Figure 1: Automate the recording of continuous readings when you hook the U1731A/U1731B/U1732A/U1732B Uncompromised quality and reliability The handheld LCR meters are housed in robust overmold and tested to stringent industrial standards ...

Page 2

... Figure 2: U1732B front view 2 Secondary display 20,000 counts resolution Data Hold function to freeze measured values Selection of test frequencies U1731A/U1731B: 120 Hz/1 kHz U1732A/U1732B: 100 Hz/120 Hz/1kHz/ 10 kHz Calibration function for greater measurement accuracy Guard terminal to be used with SMD tweezer for better noise immunity ...

Page 3

... U1731A/U1731B Electrical Specifications Accuracy is expressed as ± reading + number of least significant digits °C ±5 °C and <75% R.H. Resistance (Parallel Mode), Test Frequency = 120 Hz/1 kHz Range Maximum Display 10 MW 9.999 MW 2000 kW 1999.9 kW 200 kW 199. 19.999 kW 2000 W 1999.9 W 200 W 199. 19.999 W [1] Specifications are based on measurements performed at the test sockets and on battery operation. ...

Page 4

Capacitance (Parallel Mode), Test Frequency = 120 Hz Range Maximum Display [ 19.99 mF [2] 1000 μF 1999.9 μF 200 μF 199.99 μF 20 μF 19.999 μF 2000 nF 1999.9 nF 200 nF 199. 19.999 ...

Page 5

Inductance (Series Mode), Test Frequency = 120 Hz Range Maximum Display 1000 H 999.9 H 200 H 199. 19.999 H 2000 mH 1999.9 mH 200 mH 199. 19.999 mH Inductance (Series Mode), Test Frequency ...

Page 6

U1732A/U1732B Electrical Specifications Accuracy is expressed as ± reading + number of least significant digits °C ± 5 °C and <75% R.H. Resistance (Parallel Mode), Test Frequency = 100 Hz/120 Hz Range Maximum Display 10 MW ...

Page 7

Capacitance (Parallel Mode), Test Frequency = 100 Hz/120 Hz Range Maximum Display [ 19.99 mF [2] 1000 μF 1999.9 μF 200 μF 199.99 μF 20 μF 19.999 μF 2000 nF 1999.9 nF 200 nF 199. ...

Page 8

Inductance (Series Mode), Test Frequency = 100 Hz/120 Hz Range Maximum Display 1000 H 999.9 H 200 H 199. 19.999 H 2000 mH 1999.9 mH 200 mH 199. 19.999 mH Inductance (Series Mode), Test ...

Page 9

... Power consumption Input protection fuse Battery life Low battery indicator Operating environment Storage environment Temperature coefficient Weight Dimensions ( Safety and EMC compliance Calibration Warranty U1731A/U1731B L/C/R/D/Q 1%, 5%, 10% Test frequency Actual test setting frequency 120 Hz 120 Hz 1 kHz 1010 Hz Inductance (L): Defaults to series mode ...

Page 10

... Ordering Information U1731A U1732A Standard shipped items Standard U1731A, U1731B, U1732A and U1732B ordering include: Quick Start Guide Certificate of Calibration (CoC) Alligator clip leads 9 V Alkaline battery Option U1731A-SMD and U1732A-SMD ordering includes (For A series handheld LCR meters only) : SMD tweezer and soft carrying case in addition to the standard shipped items ...

Page 11

Agilent Email Updates www.agilent.com/find/emailupdates Get the latest information on the products and applications you select. www.lxistandard.org LXI is the LAN-based successor to GPIB, providing faster, more efficient connectivity. Agilent is a founding member of the LXI consortium. Agilent Channel Partners ...