3120-F72R-P7T1-A20Q-20

Manufacturer Part Number
3120-F72R-P7T1-A20Q-20
Description
Circuit Breaker; Therm; Rocker; Cur-Rtg 20A; Snap-In Frame; 2 Pole; Blade Snap
Manufacturer
E-T-A Circuit Protection and Control
Type
Thermalr
Datasheet

Specifications of 3120-F72R-P7T1-A20Q-20

Actuator Type
Rocker
Application
Motors, transformers, solenoids, extra low voltage wiring systems, office machines, electro-medical equipment, power supplies, communications systems, medical equipment to EN 60601
Brand/series
3120-F7 Series
Characteristic
Thermal
Color, Button
Blue
Current, Rating
20 A
Dielectric Strength
3000 VAC (Operating Area), 1500 VAC (Between 2 Poles)
Dimensions
1.69"Lx0.964"Wx1.3"H
Mounting Hole Size
1.75x0.866 "
Mounting Type
Snap-In Frame
Number Of Poles
2
Resistance, Insulation
100 Megohms (Min.)
Standards
UL Listed, CSA Certified, VDE Approved
Temperature, Operating, Maximum
60 °C
Temperature, Operating, Minimum
-30 °C
Termination
Blade
Voltage, Rating
240/50 VAC/VDC
Ul, Csa And Ccc Approval Ratings
250 VAC, 50 VDC; 0.1 to 20 Amps
Terminals
Quick-Connect 2 × 0.110" (0.250" Total)
Ambient Temperature
–22°F to 140°F
Lead Free Status / Rohs Status
RoHS Compliant part
Type: 3120-F7
Dimensions
Internal connection diagrams
E-T-As proven type 3120 in a new attractive styling (S-type TO CBE to
EN 60934 with trip free mechanism) offering the choice of single pole,
double pole with single pole protection, and double pole with protection
on both poles. Designed for snap-in panel mounting with illumination as
an option. Under overload conditions the rocker returns to the OFF
position.
Any one of the following additional function modules can be supplied
factory fitted to the rear of the switch/circuit breaker.
- Undervoltage release coil (for double pole versions only).
- Magnetic trip coil for short circuit protection.
- Magnetic trip coil for remote relay trip.
- Auxiliary contacts for status signalling.
- Mechanical slide interlock.
Approved to CBE standard EN 60934 (IEC 60934).
Available accessories: water splash protection and actuator guard to
prevent inadvertent operation.
Voltage rating:
Current ratings:
from 0.1 A to 20 A
(up to 30 A to special order, single pole only)
Number of poles:
single pole
double pole
Mounting method:
flange
Terminal design:
blade terminals
screw terminals
Actuation:
rocker
Auxiliary contacts:
with auxiliary contacts
without auxiliary contacts
Water splash protection:
with water splash protection
without water splash protection
Illumination:
with illumination
without illumination
Typical life:
0.1...16 A 50,000 operations at 1 x I
0.1...20 A 30,000 operations at 1 x I
Interrupting capacity I
0.1...2 A: 10 x I
2.5...20 A: 150 A single pole
2.5...20 A: 250 A double pole
Approvals:
VDE, CSA, UL, CCC
AC 240 V (AC 415 V to special order)
DC 50 V
UL/CSA: AC 250 V
N
cn
:
N
N
, inductive, double pole
, inductive, single pole

Related parts for 3120-F72R-P7T1-A20Q-20

3120-F72R-P7T1-A20Q-20 Summary of contents

Page 1

... Type: 3120-F7 Dimensions Internal connection diagrams E-T-As proven type 3120 in a new attractive styling (S-type TO CBE to EN 60934 with trip free mechanism) offering the choice of single pole, double pole with single pole protection, and double pole with protection on both poles. Designed for snap-in panel mounting with illumination as an option ...

Page 2

... Thermal Overcurrent Circuit Breaker 3120-F7.. Description E-T-A’s proven type 3120 in a new attractive styling (S-type TO CBE to EN 60934 with trip free mechanism) offering the choice of single pole, double pole with single pole protection, and double pole with protection on both poles. Designed for snap-in panel mounting with illumination as an option. ...

Page 3

... Rocker markings Q "I" and "0" moulded in Push button illumination (optional 3120 - 3120 - N.B. Switch only versions must be specified with -N7 or -G7 terminals. Terminals 12(k) and 22(k) are not fitted Typical time/current characteristics single or double pole load 0.1 … panel thickness ...

Page 4

... Thermal Overcurrent Circuit Breaker 3120-F7.. Dimensions Style -F7.N and F7.R 25 .984 1.89 15.5 .610 12(i) 10.7 3.5 .421 .138 21 15.5 .827 .610 blade terminals DIN 46244-C-Ms-S ( .110) flat head screw ISO1580 M3.5x5-MS tightening torque max. 0.8 Nm Style -F7.P and F7.S 34 1.34 18 ...

Related keywords