44536-1110 Sti (Scientific Technologies, Inc.), 44536-1110 Datasheet
44536-1110
Related parts for 44536-1110
44536-1110 Summary of contents
Page 1
... CM-S221 switch. The CM- S221 switch will work with many safety monitoring relays accept- ing 2 N/C safety inputs. The CM control units will monitor one to four CM switches to category 3 in accordance with EN954-1. The CM-S4 controller is designed to work with with non-contact switches with dry contacts 1 N N/O ...
Page 2
...
Page 3
... CM Series Applications ■ Typical applications are on slid- ing guard doors or swinging guard doors. L (+ve) G GS1 A1 S13 S23 GATE 1 MECHANICAL CM-S41 SAFETY SWITCHES or POWER 1 DE-SELECT EMERGENCY STOP 2 GATE 2 RUN 3 GATE 3 4 GATE 4 GATE 3 A2 S14 S24 GS3 N (-ve) In the illustration above, the guard door is open and the machine is stopped ...
Page 4
... Approvals/listings: CE marked for all applicable directives, UL and C-UL, TUV Safety category: Cat 3 per EN954-1 (internal operation) Specifications are subject to change without notice. Note: The safety contacts of the Omron STI switches are described as normally closed (N/C) i.e., with the guard closed, actuator in place, and the machine able to be started. cm-S4 24 VAC/DC ± ...
Page 5
... Approvals/listings: CE marked for all applicable directives, UL and C-UL, TUV (TUV pending for CM-S221) Specifications are subject to change without notice. Note: The safety contacts of the Omron STI switches are described as normally closed (N/C) i.e., with the guard closed, actuator in place, and the machine able to be started. ...
Page 6
Dimensions — mm/in. ■ Control Units cm-S4 75 2.95 for 75 cm-S41 2.95 22.5 cm-S21/Se 0.88 119 4.68 45 1.77 105 4.13 114.7 4.515 35 Din rail 1.38 74 2.91 119 4.68 84 3.3 CM Series 75 2.95 74 2.91 ...
Page 7
... CM Series Dimensions — mm/in. (continued) ■ Switches CM-S1 Switch NOTE: Actuator is same dimension as switch. 0.34 0.013 Actuator Ø5.8 ca. 0.23 Active Area 42 G 1.65 CM-S2 Switch 87.5 3.44 67.5 2.66 13 0.51 2.5 0.1 Active Area Center Offset 2.5 2.5 0.47 9.5 0.1 ...
Page 8
... Current Sensing Circuit 5 m cable Current Sensing Circuit Connector + 5 m cable CM Series Part no. 44536-0040 44536-0140 44536-0141 44536-0120 44536-0170 44536-0100 44536-0105 44536-1100 44536-1105 G 44536-1110 44536-1159 44536-0200 44536-0205 44536-0221 44536-0300 44536-0305 44536-3100 44536-3105 44536-3159 44536-0710 44536-0720 44536-0721 44536-0730 44536-0711 44536-0731 44536-0800 ...