FLUKE-87-V-EX Fluke, FLUKE-87-V-EX Datasheet - Page 2

no-image

FLUKE-87-V-EX

Manufacturer Part Number
FLUKE-87-V-EX
Description
INTRINSICALLY SAFE TRUE RMS MULTIMETER
Manufacturer
Fluke
Datasheet

Specifications of FLUKE-87-V-EX

Lead Free Status / Rohs Status
RoHS Compliant part
Alligator Clip Set, instruction manual in English,
French, German and CD Rom with additional
manuals in multiple languages.
Ordering Information
Fluke-87-5-Ex Intrinsically Safe
Included
DMM with holster, TL75 Test Lead Set, AC72
Summary specifications
Measurements restriction
in Ex-hazardous area
General Specifications
*with low pass filter; 3 db @ 1 kHz
Specifications
Voltage dc
Voltage ac
Current dc
Current ac
Resistance
Capacitance
Frequency
Duty cycle
Temperature measurement
80BK Temperature Probe
Conductance
Diode
Duty cycle range
Environmental specifications
Safety specifications
Mechanical and
True-rms Multimeter
Maximum voltage:
Accuracy:
Maximum resolution:
Maximum voltage:
Accuracy:
AC bandwidth:
Maximum resolution:
Maximum amps:
Amps accuracy:
Maximum resolution:
Maximum amps:
Amps accuracy:
Maximum resolution:
Maximum resistance:
Accuracy:
Maximum resolution:
Maximum capacitance:
Accuracy:
Maximum resolution:
Maximum frequency:
Accuracy:
Maximum resolution:
Maximum duty cycle:
Accuracy:
Maximum resolution:
Range:
Range:
Accuracy:
Maximum conductance:
Accuracy:
Maximum resolution:
Range:
Resolution:
Accuracy:
Accuracy:
Voltage:
Current:
Operating temperature:
Storage temperature:
Humidity (w/o condensation):
Operating altitude:
Overvoltage category:
Agency approvals:
ATEX specification:
Agency approvals:
Size:
Weight:
Weight with holster:
Display (digital):
Display analog:
Warranty:
Battery life (Alkaline):
Shock:
Vibration:
Fluke. Keeping your world
Fluke Corporation
PO Box 9090, Everett, WA USA 98206
Fluke Europe B.V.
PO Box 1186, 5602 BD
Eindhoven, The Netherlands
1000 V
± (0.05 % + 1)
10 µV
1000 V
± (0.7 % + 2) True-rms
20 kHz*
0.1 mV
10 A (20 A for 30 seconds maximum)
± (0.2 % + 2)
0.01 µA
10 A (20 A for 30 seconds maximum)
± (1.0 % + 2) True-rms
0.1 µA
50 MW
± (0.2 % + 1)
0.1 W
9,999 µF
± (1 % + 2)
0.01 nF
200 kHz
± (0.005 % + 1)
0.01 Hz
99.90 %
± (0.2 % per khz +0.1 %)
0.10 %
-200.0 °C to 1090 °C (-328 °F to 1994 °F)
excluding probe
-40.0 °C to 260 °C (-40 °F to 500 °F)
2.2 °C or 2 % whichever is greater
60.00 nS
± (1.0 % + 10)
0.01 nS
3 V
1 mV
± (2 % + 1)
Within ± (0.2 % per kHz + 0.1 %)
≤ 65 V
≤ 5 A
-20 °C to +55 °C
-40 °C to +60 °C
0 % to 90 % (0 °C to 35 °C)
0 % to 70 % (35 °C to 55 °C)
2000 m
EN 61010-1 to 1000 V CAT III, 600 V CAT IV
CSA, TÜV
EX II 2 G EEx ia IIC T4
ZELM 05 ATEX 027
201 x 98 x 52 mm (with holster)
1.09 lbs
1.46 lbs
6000 counts updates 4/sec.
19,999 counts in high-resolution mod
32 segments, updates 40/sec.
1 year
~400 hours typical, without backlight
1 Meter drop per IEC 61010-1:2001
Per MIL-PRF-28800 for a Class 2 instrument
up and running.
For more information call:
In the U.S.A. (800) 443-5853 or
Fax (425) 446-5116
In Europe/M-East/Africa +31 (0) 40 2675 200 or
Fax +31 (0) 40 2675 222
In Canada (800)-36-FLUKE or
Fax (905) 890-6866
From other countries +1 (425) 446-5500 or
Fax +1 (425) 446-5116
Web access: http://www.fluke.com
©2006 Fluke Corporation. All rights reserved.
Printed in U.S.A. 5/2006 2523579 D-EN-N Rev B