RP-LS42F-75LE BANNER ENGINEERING, RP-LS42F-75LE Datasheet
RP-LS42F-75LE
Specifications of RP-LS42F-75LE
Related parts for RP-LS42F-75LE
RP-LS42F-75LE Summary of contents
Page 1
... Heavy-duty thermoplastic housing, rated IP67 and NEMA 4, suitable for demanding industrial environments • Innovative design provides quick, easy rope fixing and tensioning on models RP-LS42F-75LE and RP-LS42F-75LF • Rope spans (245') • Both safety contacts are closed with normal rope tension, and open when rope is pulled or if rope breaks (or if tension is reduced from normal amount) • ...
Page 2
... Safety and Health Administration (OSHA). Whether or not any particular rope pull switch installation meets all applicable OSHA requirements depends upon factors that are beyond the control of Banner Engineering Corp. These factors include the details of how the switches are applied, installed, wired, operated, and maintained. ...
Page 3
... Rope Pull Emergency Stop Switches – Built-in † Model E-Stop Turnbuckle RP-LS42F-75L RP-LS42F-75LE Yes Yes RP-LS42F-75LF No Yes NOTE: This symbol for a positive-opening safety contact (IEC 60947-5-1) is used in the switching diagram to identify the point in actuator travel where the normally-closed safety contact is fully open. ...
Page 4
... Use pulleys (recommended) or eye bolts at each support point. A pulley must be used when routing the rope around a corner, regardless of the angle. 4 P/N 67709 rev. A RP-LS42F-75L.. Series Figure 2. Tightening the rope into the internal turnbuckle (models RP-LS42F-75LE and RP-LS42F-75LF) Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 ...
Page 5
... Installing Model RP-LS42F-75LE or RP-LS42F-75LF These models have their own internal turnbuckle and clamp to tension the rope and to hold it in place. This innovative design provides for quick and easy rope fixing and tensioning, and means no external turnbuckle is required, nor is any additional clamp required at the switch end of the rope ...
Page 6
... Dual-Channel Output: Wire contacts 21/22 and 41/42 independently to the two safety module inputs (see Figure 6). P/N 67709 rev. A desired wiring terminal. terminal jaws; insert wire. RP-LS42F-75L.. Series Dual-Channel Safety Device CH 2 Figure . Wire the two switch contacts in series Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 CH 1 ...
Page 7
... Models RP-LS42F-75L and RP-LS42F-75LF: Pull the blue reset button; the arrows should then be centered in the tensioning indicator window. Model RP-LS42F-75LE: The E-stop can be reset only when proper tension is indicated. Turn the yellow knob clockwise until the blue arrow is in the “I” position (indicating that the latch has been reset) ...
Page 8
... Adapter supplied to convert M20 x 1.5 to ½" NPT threaded entrance Construction High-impact thermoplastic housing; zinc die-cast actuator Environmental Rating NEMA 4, IEC IP67 Operating Conditions Temperature: Weight RP-LS42F-75L: 0.48 Kg (1.05 lbs.) RP-LS42F-75LE: 0.65 Kg (1.43 lbs.) RP-LS42F-75LF: 0.65 Kg (1.43 lbs.) Certifications 8 P/N 67709 rev. A RP-LS42F-75L.. Series Specifications AWG (1 ...
Page 9
... Rope Pull Emergency Stop Switches – RP-LS42F-75LE 256.0 mm (10.08") 88.0 mm (3.46") Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 Dimensions RP-LS42F-75L 124.0 mm (4.88") 45.0 mm 5.0 mm (1.77") (0.20") 42.0 mm 78.3 mm (1.65") (3.08") 294.0 mm (11.57") RP-LS42F-75L.. Series 224.0 mm (8.82") 30.0 mm (1.18") RP-LS42F-75LF 78 ...
Page 10
... RPA-S4 clamping, tensioning, and overload protection Clamp Thimble NOTE: If model RPA-S4-1 tensioning spring is used, eliminate eye bolt, spring, protector cable, clamp and thimble from versions shown here. Figure 7. Wire rope assembly components 10 P/N 67709 rev. A RP-LS42F-75L.. Series ...
Page 11
... M20 x 1.5 SI-QS-CGM20 Plastic Size Model* ½"-14 SI-QS-M20 NPT Plastic *NOTE: One conduit adapter is supplied with each switch. Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 Accessories, continued Cable Glands Used with For Cable Switch Models Diameters 6.0 to 12.0 mm All (0.24" ...
Page 12
... Rope Pull Emergency Stop Switches – WARRANTY: Banner Engineering Corp. warrants its products to be free from defects for one year. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture found to be defective at the time it is returned to the factory during the warranty period. This warranty does not cover damage or liability for the improper application of Banner products ...