41692-500ML MG Chemicals, 41692-500ML Datasheet - Page 2

Tin and Solder stripper

41692-500ML

Manufacturer Part Number
41692-500ML
Description
Tin and Solder stripper
Manufacturer
MG Chemicals
Type
Tin and Solder Stripperr
Datasheet

Specifications of 41692-500ML

Dwell Time
(Spray) 20 seconds — 2 minutes (Immersion) 1minute — 5 minutes
Special Features
Tin Stripper
Temperature Range
21°C - 35°C (70°F - 95°F)
Weight
500 ML
Lead Free Status / Rohs Status
RoHS Compliant part Hazardous Materials
The Tin & Solder Striper can also be maintained using specific gravity to control automatic feed and
bleed additions. The specific gravity controller should be set to maintain a specific gravity between
1.250 and 1.300. Lower specific gravity provides greater speed while high specific gravity will allow
more economical operation.
Tin & Solder Striper can hold 75-100 g/L of tin metal or 125-150 g/L of tin/lead. To determine the
volume of solution used per panel, it is necessary to determine the amount of tin or tin/lead per panel.
For tin, 1mil sq.ft. is equivalent to 21 grams 91 micron sq. meter is equivalent to 8.8 grams). The
volume of solution per panel can then be calculated as shown below.
For tin:
Tin & Solder Striper solution used = mil/sq.ft./panel x 18 g/mil sq.ft. x 1L/100g
For tin/lead:
Tin & Solder Striper solution used = mil sq.ft./panel x 21 g/mil sq.ft. x 1L/150g
EQUIPMENT
All materials in contact with the solution should be constructed of quartz, glass, 316 stainless steel, titanium or plastics
©
such as polypropylene, high density polyethylene, PVC, or Teflon
. Plastisol coatings are also acceptable.
WASTE TREATMENT
Adjust the pH to 8.5 with caustic soda to precipitate the metals. Dispose of all meterials in accordance wth all applicable
federal, state/province, and local requirements.
SAFETY
Proper safety equipment including face and eye protection, gloves, boots, and aprons should be used when handling this
material. In case of exposure, flush the affected area with clean water and CONTACT A PHYSICIAN. Proper ventilatioin
should be provided to avoid exposure to mists and vapors.
Consult the Material Safety Data Sheet for safety, health and environmental information.