EX-F71 Panasonic Electric Works, EX-F71 Datasheet

no-image

EX-F71

Manufacturer Part Number
EX-F71
Description
Sensor, Leak Detection, Amp. Built In, SUS Mounting, 12-24V, NPN
Manufacturer
Panasonic Electric Works
Type
Levelr
Datasheet

Specifications of EX-F71

Brand/series
EX-F70
Current, Switching
50 mA
Function
Level
Ip Rating
IP67
Output
NPN
Primary Type
Photoelectric
Sensing Mode
Retro-Reflective
Technology
Photoelectric
Termination
Cable
Voltage, Supply
24 VDC
Voltage, Switching
30 VDC
Lead Free Status / Rohs Status
RoHS Compliant part
EX-F60/70 Photoelectric Sensors
The EX-F70/F60 series of leak detection sensors offer a unique and reliable method of protecting your equipment against
leaks. Using a capillary effect, the sensor utilizes the change in refractive index to detect small leaks and viscous liquids. The
built-in amplifier sensor offers a compact design, and is available in general purpose (water detection) and chemical-resistant
types. A convenient LED indicator allows for simple verification of fault conditions. There is no need for sensitivity
adjustments, and two simple mounting bracket styles facilitate simple installation.
Model Name
Sort
EX-F61
EX-F61-PN
EX-F62
EX-F62-PN
EX-F71
EX-F71-PN
EX-F72
EX-F72-PN
Leak Detection Sensor
Type
Sort
Leak Detection, Chemical Resistant
Leak Detection, Chemical Resistant
Leak Detection, Chemical Resistant
Leak Detection, Chemical Resistant
Leak Detection, General Purpose
Leak Detection, General Purpose
Leak Detection, General Purpose
Leak Detection, General Purpose
Output Configuration
Sort
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
Sensing Object
Sort
Chemical Solution
Chemical Solution
Chemical Solution
Chemical Solution
Water
Water
Water
Water
Sensing Configuration
Sort
Leak Detection, Contact
Leak Detection, Contact
Leak Detection, Contact
Leak Detection, Contact
Leak Detection, Contact
Leak Detection, Contact
Leak Detection, Contact
Leak Detection, Contact

Related parts for EX-F71

EX-F71 Summary of contents

Page 1

... A convenient LED indicator allows for simple verification of fault conditions. There is no need for sensitivity adjustments, and two simple mounting bracket styles facilitate simple installation. Model Name Sort EX-F61 EX-F61-PN EX-F62 EX-F62-PN EX-F71 EX-F71-PN EX-F72 EX-F72-PN Type Output Configuration Sort Sort Leak Detection, Chemical Resistant NPN ...

Page 2

... Note: M4 stud bolts have been welded to this unit. M4 nuts are not supplied with the sensor. Please arrange it separately. Assembly dimensions EX-F71(-PN) with SUS mounting bracket "2.5 "0.098 cable 6.562 ft long Note stud bolt has been welded to this unit. ...

Page 3

... Notes: 4) Liquid being detected should also be kept within the rated ambient temperature range. Notes: 5) PVC mounting bracket may not be used depending on type or viscosity etc. of the agent. For details, please contact our office. 6) The mounting bracket for EX-F71 General purpose EX-F71 EX-F72 ...

Related keywords