E3JU-R5M4-3 Omron Automation, E3JU-R5M4-3 Datasheet - Page 8

no-image

E3JU-R5M4-3

Manufacturer Part Number
E3JU-R5M4-3
Description
Sensor; Relay; Polarized Retroreflective Sensing Mode; Photoelectric; 5 m
Manufacturer
Omron Automation
Type
Retroreflectiver
Datasheet

Specifications of E3JU-R5M4-3

Body Style
Rectangular
Dimensions
1.80 in. L x 2.96 in. H
Function
Proximity
Indicator
Light Incident (Red LED), Output Operation (Yellow LED), Stability (Green LED)
Light Source
Polarized Red LED
Material, Body
ABS⁄Polycarbonate
Material, Cover
Polycarbonate
Material, Lens
Plastic⁄PMMA
Output
Relay
Power Consumption
3.5 W (Max.)
Primary Type
Photoelectric
Range, Measurement
5 m
Response Time
12 ms (Max.)
Sensing Mode
Polarized Retro-Reflective
Standards
UL Listed, CSA Certified, CE Marked
Technology
Photoelectric
Temperature, Operating
-25 to +55 °C
Voltage, Supply
24-240/12-240 VAC/VDC
Weight
10.5 Oz.
Lead Free Status / Rohs Status
RoHS Compliant part
E3JU
J SENSITIVITY ADJUSTMENT (DIFFUSE REFLECTIVE SENSORS)
8
Steps
Function
Sensing
condition
Sensitivity
adjuster
Indicators
Procedure
Step 1
Determine position A
Photoelectric sensor
Place target at the desired sensing
distance. Set sensitivity adjuster to the
minimum scale position, and gradually
increase sensitivity by turning the
sensitivity adjuster clockwise until the
Light Incident indicator (red LED)
turns ON. Position A designates the
point at which the LED has turned ON.
Min
A
ON
LIGHT
Indicator (red)
Target
Max
Incident
Background
Step 2
Determine position B
Remove the target. Starting from the
maximum scale position, gradually
decrease sensitivity by turning the
sensitivity adjuster counterclockwise
until the Light Incident indicator (red
LED) turns OFF. Position B
designates the point at which the LED
has turned OFF.
Photoelectric sensor
Min
OFF
Target
LIGHT
Indicator (red)
B
Max
Incident
Background
Step 3
Adjust to optimum setting
Set the sensitivity indicator to the
position between Positions A and B (in
some cases, Positions A and B are
opposite of the above example). To
insure stable sensor operation, the
green stability indicator should be fully
“on” in both the sensing and
non-sensing conditions.
Photoelectric sensor
Min
A
OFF
LIGHT Incident
Indicator (red)
Target
B
Max
Background
E3JU

Related parts for E3JU-R5M4-3