FPG-COM2-A Panasonic Electric Works, FPG-COM2-A Datasheet - Page 7

no-image

FPG-COM2-A

Manufacturer Part Number
FPG-COM2-A
Description
ACCESSORY, 2 RS232C COMM. CASSETTE
Manufacturer
Panasonic Electric Works
Type
Communicationsr
Datasheet

Specifications of FPG-COM2-A

Brand/series
FPG
Primary Type
Option
For Use With
Micro Controllers
FP
14
1. General Specifications
2. CC-Link Communication Specifications
Available for Open Network CC-Link
I Specification
Rated operating voltage
Operating voltage range
Rated current consumption
Allowed momentary
power off time
Ambient temperature
Storage temperature
Ambient humidity
Storage humidity
Breakdown voltage
Insulation resistance
Vibration resistance
Shock resistance
Noise immunity
Operating condition
Weight
Version
Communication method
Transmission speed
Max.
transmission
distance
Interface
Station type
Number of occupied stations
Note 1)
Σ
FP
/FP0
Σ
2.5 M bit/s
625 k bit/s
156 k bit/s
10 M bit/s
5 M bit/s
CC-Link Slave Unit
FPG-CCLS
24 V DC
21.6 to 26.4 V DC
CC-Link Unit: 40 mA or less/24 V DC
Increase amount in the control unit when expansion units are added:
40 mA or less/24 V DC
10 ms
0 to
-20 to
30 to 85% RH (non-condensing)
30 to 85% RH (non-condensing)
Between RS485 terminal and power supply terminal/function earth:
500 V AC for 1minute
Between RS485 terminal and power supply terminal/function earth:
Min. 100 (measured with a 500 V DC megger)
10 to 55 Hz, 1 cycle/min.
Double amplitude: 0.75
98 m/s
1,000 V p-p with pulse width 50 ns and 1 µs (based on in-house measurements)
Free from corrosive gases and excessive dust
FP Σ CC-Link slave unit: Approx. 90 g, FP0 CC-Link slave unit: Approx. 80 g
CC-Link Ver.1.10
Broadcast polling method
10 M bit/s, 5 M bit/s, 2.5 M bit/s, 625 k bit/s, 156 k bit/s
RS485
Remote device station
FP
Σ
+55°C/+32 to +131°F
: 1 to 4 stations (switch changeover), FP0: 1 station
CC-Link high-performace cable
+70°C/-4 to +158°F
2
CC-Link Slave Unit
or more, 4 times on 3 axes
Ver.1.10 CC-Link cable
1200 m
100 m
160 m
400 m
900 m
mm/0.030
in., 10 min. on 3 axes
FP0 CC-Link Slave Unit
FP0-CCLS
CC-Link cable
1200 m
100 m
150 m
200 m
600 m
I Features
1. Fit into Open Network System
2. Advanced I/O Points and Data
I Unit Differences
Note 1)
Note 2)
PLC to be
connected
Max.
I/O points
Max. data
Limitations
Recom-
mendation
K.J.T
R
Even when PLCs from other
manufacturers are used, a system with
high-speed positioning, temperature
control and S-LINK connection can be
established.
Read/Write
FP
points each, 16-word data read/write
FP0 CC-Link slave unit: Max.16 I/O
points each, 4-word data read/write
Thermocouple
100 to 299.9°C
Σ
300 to 1500°C
Length of the multi-drop connected cables at
both ends
The cable length has restrictions in
communication speed, CC-Link version, and
dedicated cables to be used.
For details concerning the CC-Link, refer to
the CC-Link Partner Association.
When an FP0 thermocouple unit is used with
an FP0 CC-Link slave unit, the measurement
accuracy of the thermocouple unit which is
installed on the left of the CC-Link slave unit
is as shown in the table below.
CC-Link slave unit: Max. 112 I/O
0 to 99.9°C
Read: 16-word data,
Write: 16-word data
When CC-Link is
mainly used
FP Σ CC-Link
Output: 112
Input: 112,
slave unit
FP Σ
specifications
Standard
0.8°C
2.5°C
3°C
2°C
Read: 4-word data,
Write: 4-word data
• One FP0 CC-Link
• When an FP0 CC-
When S-LINK and
CC-Link are used
together
slave unit can be
installed on the ex-
tremely right in the
expansion position.
Link slave unit is
used together with
an FP0 thermocou-
ple unit in a sys-
tem, the measure-
ment accuracy of
the thermocouple
unit is as shown
in
FP0 CC-Link
note 2)
Output: 16
slave unit
Input: 16,
FP Σ /FP0
slave unit with a
When CC-Link
thermocouple
below.
2°C
6°C
5°C
4°C
unit