10074C Agilent Technologies Test Equipment, 10074C Datasheet - Page 7

no-image

10074C

Manufacturer Part Number
10074C
Description
Probe; 1.5 m; 150 MHz; 10 Megohms; Approx 15 pF; lt 2.33 ns; 10:1;
Manufacturer
Agilent Technologies Test Equipment
Datasheet

Specifications of 10074C

Attenuation
10:1
Bandwidth
150 MHz
Capacitance, Input
Approx 15 pF
Length, Cable
1.5 m
Resistance, Input
10 Megohms
Active Differential Probes
• 20 MHz to 1.5 GHz bandwidth
• Switchable attenuation
• Measure up to 600 V CAT III and
N2772A 20 MHz differential probe
Use the Agilent N2772A
differential probe with any of the
5000, 6000, or 7000 Series oscil-
loscopes to safely measure float-
ing circuits with the oscilloscope
grounded. With 20 MHz band-
width and switchable attenuation
of 20:1 and 200:1, it provides the
versatility for a broad range of
applications including high-volt-
age
circuits, motor controls, power
supply design, and electronic
high-power converters.
Each probe comes with 2 sharp
probe tips for use on small
components and in tight places,
2 retractable probe hooks for
connecting to smaller wires and
through-hole components, and
2-alligator clips for use with
larger cables.
This probe requires a 9 V battery
or Agilent N2773A power supply.
Specifications for N2772A
differential probe
Bandwidth
Risetime
Attenuation Ratio
High CMRR
Max Input
voltage to ground
Max differential
input voltage
Measure up to 600 V CAT III
Maximum Number
of Probes Supported
by 5000/6000/7000 Series
1000 V CAT II
20 MHz
17.5 ns
20:1 and 200:1 selectable
via switch on probe
80 dB @ 60 Hz,
50 dB @ 1 MHz
600 V CAT III
1000 V CAT II
1000 VDC or
1000 Vrms or
1200 VDC + peak AC
4
1141A 200 MHz differential probe
The 1141A is a 1x FET differen-
tial probe with 200-MHz band-
width and a 3000:1 CMRR. The
probe has a high-input resistance
and low input capacitance of 7-pF
to minimize circuit loading. The
1141A must be used with 1142A
probe control and power module,
which controls input coupling
modes dc, dc with variable offset,
and dc reject. Two attenuators,
10x and 100x are provided to
expand the linear differential
input range to ±30V. This probe
works with any 50-Ω input
oscilloscope including 5000 and
6000 Series.
Specifications for 1141A
differential probe
Bandwidth
Risetime
(Calculated)
Attenuation Ratio
High CMRR
Input Impedance
Maximum Input
Voltage
Maximum Number
of Probes Supported
by 5000/6000/7000 Series
200 MHz
1.75 ns
10:1 and 100:1
with attenuater
3000:1 at 1-MHz
10:1 at 100-MHz
Between inputs:
1 MΩ, 7 pF
200 Vdc + peak ac
(probe alone)
500 Vdc + peak ac
(with attenuator)
4
Ordering information for Agilent
differential probes and power supply
N2772A
N2773A
1141A
1142A
Derating of each input for the N2772A
N2772 20 MHz differential probe
1141A 200 MHz differential probe
20 MHz differential
probe, supplied with a
retractable hook, sharp
probe tips and alligator clips
Power supply for N2772A
200 MHz differential
probe
Probe control and
power module for 1141A
7