G310C000 Red Lion Controls, G310C000 Datasheet - Page 3

no-image

G310C000

Manufacturer Part Number
G310C000
Description
OPERATOR INTERFACE; COLOR TFT LCD; 10 INCH; 24V; 8MB FLASH MEMORY
Manufacturer
Red Lion Controls
Type
Color Graphicr
Datasheet

Specifications of G310C000

Dimensions
12.83 W × 9.5 H In.
Display Size
10 In.
Memory
8 Mb Flash
Mounting Type
Panel
Primary Type
Operator Interface
Resolution
640 × 480 Pixel LCD
Resolution, Display
640 × 480
Size
10 In. Color TFT
User Interface
Touchscreen
Voltage, Supply
24 V
Lead Free Status / Rohs Status
RoHS Compliant part
MOUNTING INSTRUCTIONS
out diagram and a template are provided. Care should be taken to remove any
loose material from the mounting cut-out to prevent that material from falling
into the operator interface during installation. A gasket is provided to enable
sealing to NEMA 4X/IP66 specification. Install the 14 kep nuts provided and
tighten evenly for uniform gasket compression.
N-m) may cause damage to the front panel.
CONNECTING TO EARTH GROUND
should be connected to earth ground (protective earth).
CONFIGURING A G310
download from Red Lion’s website, or it can be purchased on CD. Updates to
Crimson for new features and drivers are posted on the website as they become
available. By configuring the G310 using the latest version of Crimson, you are
assured that your unit has the most up to date feature set. Crimson software can
configure the G310 through the RS232 PGM port, USB port, or CompactFlash.
connector. The driver needed to use the USB port will be installed with Crimson.
If this driver has not been installed, it can be downloaded from the website.
connect to the DB9 COM port of your computer. If you choose to make your
own cable, use the “G310 Port Pin Out Diagram” for wiring information.
file and firmware on the CompactFlash card. The card is then inserted into the
target G3 and powered. Refer to the Crimson literature for more information on
the proper names and locations of the files.
CABLES AND DRIVERS
communication types. A list of these drivers and cables along with pin outs is
available from Red Lion’s website. New cables and drivers are added on a
regular basis. If making your own cable, refer to the “G310 Port Pin Outs” for
wiring information.
I
C
This operator interface is designed for through-panel mounting. A panel cut-
Note: Tightening the kep nuts beyond a maximum of 17 inch-pounds (1.92
Each G310 has a chassis ground terminal on the back of the unit. Your unit
The G310 is configured using Crimson software. Crimson is available as a free
The USB port is connected using a standard USB cable with a Type B
The RS232 PGM port uses a programming cable made by Red Lion to
The CompactFlash can be used to program a G3 by placing a configuration
Red Lion has a wide range of cables and drivers for use with many different
NSTALLING AND
OMMUNICATING
ALL NONINCENDIVE CIRCUITS MUST BE WIRED USING
DIVISION 2 WIRING METHODS AS SPECIFIED IN ARTICLE 501-
4 (b), 502-4 (b), AND 503-3 (b) OF THE NATIONAL ELECTRICAL
CODE, NFPA 70 FOR INSTALLATION WITHIN THE UNITED
STATES, OR AS SPECIFIED IN SECTION 19-152 OF CANADIAN
ELECTRICAL CODE FOR INSTALLATION IN CANADA.
The protective conductor terminal is bonded to conductive
parts of the equipment for safety purposes and must be
connected to an external protective earthing system.
All tolerances ±0.010" (±0.25 mm).
P
W
OWERING THE
ITH THE
3
Maintaining isolation between earth ground and signal common is not required
to operate your unit. But, other equipment connected to this unit may require
isolation between signal common and earth ground. To maintain isolation
between signal common and earth ground care must be taken when connections
are made to the unit. For example, a power supply with isolation between its
signal common and earth ground must be used. Also, plugging in a USB cable
may connect signal common and earth ground.
POWER SUPPLY REQUIREMENTS
requires a 24 VDC power supply rated at 50 W. Your unit may draw
considerably less the rated power depending upon the options being used. As
additional features are used your unit will draw increasing amounts of power.
Items that could cause increases in current are additional communications,
optional communications card, CompactFlash card, and other features
programmed through Crimson.
the unit is to operate reliably. Please take care to observe the following points:
USB, DATA TRANSFERS FROM THE
COMPACTFLASH CARD
driver must be installed on your computer. This driver is installed with Crimson
and is located in the folder C:\Program Files\Red Lion Controls\Crimson
2.0\Device\ after Crimson is installed. This may have already been
accomplished if your G310 was configured using the USB port.
follow “Mounting the CompactFlash” instructions in the Crimson 2 user manual.
The chassis ground is not connected to signal common of the unit.
1. USB’s shield may be connected to earth ground at the host. USB’s shield
The G310C requires a 24 VDC power supply rated at 33 W, and the G310S
In any case, it is very important that the power supply is mounted correctly if
In order to transfer data from the CompactFlash card via the USB port, a
Once the driver is installed, connect the G310 to your PC with a USB cable, and
G310
in turn may also be connected to signal common.
– The power supply must be mounted close to the unit, with usually not
– The wire used to connect the operator interface’s power supply should
– A power supply with a Class 2 or SELV rating is to be used. A Class 2
more than 6 feet (1.8 m) of cable between the supply and the operator
interface. Ideally, the shortest length possible should be used.
be at least 22-gage wire. If a longer cable run is used, a heavier gage
wire should be used. The routing of the cable should be kept away from
large contactors, inverters, and other devices which may generate
significant electrical noise.
or SELV power supply provides isolation to accessible circuits from
hazardous voltage levels generated by a mains power supply due to
single faults. SELV is an acronym for “safety extra-low voltage.” Safety
extra-low voltage circuits shall exhibit voltages safe to touch both under
normal operating conditions and after a single fault, such as a
breakdown of a layer of basic insulation or after the failure of a single
component has occurred.
WARNING - DO NOT CONNECT OR DISCONNECT CABLES
WHILE POWER IS APPLIED UNLESS AREA IS KNOWN TO BE
NON-HAZARDOUS. USB PORT IS FOR SYSTEM SET-UP AND
DIAGNOSTICS AND IS NOT INTENDED FOR PERMANENT
CONNECTION.