RS2-4TX/1FX EEC Hirschmann Automation and Control, RS2-4TX/1FX EEC Datasheet - Page 2

no-image

RS2-4TX/1FX EEC

Manufacturer Part Number
RS2-4TX/1FX EEC
Description
Ethernet; Switch; Unmanaged; DIN Rail; 4XRJ45 10/100 MBPS Port; 1X100MBPS Fbr Port
Manufacturer
Hirschmann Automation and Control
Datasheet

Specifications of RS2-4TX/1FX EEC

Lead Free Status / Rohs Status
RoHS Compliant part
RS2-3TX/2FX-SM EEC
943 772-001
Unmanaged Industrial ETHERNET Rail Switch,
store and forward switching mode, Ethernet (10
Mbit/s) and Fast-Ethernet (100 Mbit/s)
3 x 10/100BASE-TX, TP cable, RJ45 sockets,
auto-crossing, auto-negotiation, auto-polarity, 2
x 100BASE-FX, SM cables, SC sockets
1 plug-in terminal block, 5-pin
0 - 100 m
0 - 32.5 km, 16 dB link budget at 1300 nm, A =
0.4 dB/km, 3 dB reserve, D = 3.5 ps/(nm x km)
any
24 V DC (-25% to +30%)
max. 230 mA
max. 5,9 W at 24 V DC
LEDs (power, link status, data, error), signal
contact / fault relais (24 V DC / 1 A)
fedundant 24 V power supply
-40 °C to +70 °C
-40 °C to +85 °C
10% to 95%
47.2 years; MIL-HDBK 217F: Gb 25 °C
47 mm x 135 mm x 111 mm
DIN Rail 35 mm
320 g
IP 20
15 g, 11 ms duration, 18 shocks
1 mm, 2 Hz - 13.2 Hz, 90 min.; 0.7g, 13.2 Hz -
100 Hz, 90 min.; 3.5 mm, 3 Hz - 9 Hz, 10
cycles, 1 octave/min.; 1g, 9 Hz - 150 Hz, 10
cycles, 1 octave/min.
6 kV contact discharge, 8 kV air discharge
10 V/m (80 - 1000 MHz)
2 kV power line, 1 kV data line
power line: 2 kV (line/earth), 1 kV (line/line), 1 kV
data line
3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80
MHz)
FCC CFR47 Part 15 Class A
EN 55022 Class A
cUL 508 (E175531)
cUL 1604 Class 1 Div 2 (E203960)
cUL 60950 (E168643)
Germanischer Lloyd (15 662 - 00 HH)
device, terminal block, operating manual
rail power supply RPS 30, RPS 80 EEC or RPS
120 EEC, 19” installation frame
RS2-4TX EEC
943 819-001
Unmanaged Industrial ETHERNET Rail-Switch,
store and forward switching mode, Ethernet (10
Mbit/s) and Fast-Ethernet (100 Mbit/s)
4 x 10/100BASE-TX, TP cable, RJ45 sockets,
auto-crossing, auto-negotiation, auto-polarity
1 plug-in terminal block, 5-pin
0 - 100 m
any
24 V DC power supply (-25% to +30%)
max. 180 mA
max 4,8 W at 24 V DC
LEDs (power, link status, data, error), signal
contact / fault relais (24 V DC / 1 A)
redundant 24 V power supply
-40 °C to +70 °C
-40 °C to +85 °C
10% to 95%
68.5 years; MIL-HDBK 217F: Gb 25 °C
47 mm x 135 mm x 111 mm
DIN Rail 35 mm
300 g
IP 20
15 g, 11 ms duration, 18 shocks
1 mm, 2 Hz - 13.2 Hz, 90 min.; 0.7g, 13.2 Hz -
100 Hz, 90 min.; 3.5 mm, 3 Hz - 9 Hz, 10
cycles, 1 octave/min.; 1g, 9 Hz - 150 Hz, 10
cycles, 1 octave/min.
6 kV contact discharge, 8 kV air discharge
10 V/m (80 - 1000 MHz)
2 kV power line, 1 kV data line
power line: 2 kV (line/earth), 1 kV (line/line), 1 kV
data line
3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80
MHz)
FCC CFR47 Part 15 Class A
EN 55022 Class A
cUL 508 (E175531)
cUL 1604 Class 1 Div 2 (E203960)
cUL 60950 (E168643)
Germanischer Lloyd (15 662 - 00 HH)
device, terminal block, operating manual
rail power supply RPS 30, RPS 80 EEC or RPS
120 EEC, 19” installation frame
RS2-4TX/1FX EEC
943 773-001
Unmanaged Industrial ETHERNET Rail Switch,
store and forward switching mode, Ethernet (10
Mbit/s) and Fast-Ethernet (100 Mbit/s)
4 x 10/100BASE-TX, TP cable, RJ45 sockets,
auto-crossing, auto-negotiation, auto-polarity, 1
x 100BASE-FX, MM cable, SC sockets
1 plug-in terminal block, 5-pin
0 - 100 m
0 - 5000 m, 8 dB link budget at 1300 nm, A = 1
dB/km, 3 dB reserve, B = 800 MHz x km
0 - 4000 m, 11 dB link budget at 1300 nm, A =
1 dB/km, 3 dB reserve, B = 500 MHz x km
any
24 V DC (-25% to +30%)
max. 220 mA
max. 5,4 W at 24 DC
LEDs (power, link status, data, error), signal
contact / fault relais (24 V DC / 1 A)
redundant 24 V power supply
-40 °C to +70 °C
-40 °C to +85 °C
10% to 95%
51.4 years; MIL-HDBK 217F: Gb 25 °C
47 mm x 135 mm x 111 mm
DIN Rail 35 mm
320 g
IP 20
15 g, 11 ms duration, 18 shocks
1 mm, 2 Hz - 13.2 Hz, 90 min.; 0.7g, 13.2 Hz -
100 Hz, 90 min.; 3.5 mm, 3 Hz - 9 Hz, 10
cycles, 1 octave/min.; 1g, 9 Hz - 150 Hz, 10
cycles, 1 octave/min.
6 kV contact discharge, 8 kV air discharge
10 V/m (80 - 1000 MHz)
2 kV power line, 1 kV data line
power line: 2 kV (line/earth), 1 kV (line/line), 1 kV
data line
3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80
MHz)
FCC CFR47 Part 15 Class A
EN 55022 Class A
cUL 508 (E175531)
cUL 1604 Class 1 Div 2 (E203960)
cUL 60950 (E168643)
Germanischer Lloyd (15 662 - 00 HH)
device, terminal block, operating manual
rail power supply RPS 30, RPS 80 EEC or RPS
120 EEC, 19” installation frame

Related parts for RS2-4TX/1FX EEC