U1272A Agilent Technologies Test Equipment, U1272A Datasheet - Page 9

no-image

U1272A

Manufacturer Part Number
U1272A
Description
DMM, Handheld, Orange, 40 Hz - 100 Khz
Manufacturer
Agilent Technologies Test Equipment
Datasheet
3.
4.
AC specifications for U1271A
1. Notes for voltage specifications:
2. Notes for current specifications:
True RMS AC
Voltage
Function
True RMS AC
Notes for current specifications:
Notes for diode specifications:
Function
Current
Overload protection for 300 μA to 300 mA range: 0.44 A/1000 V; 10 × 35 mm 30 kA fast-acting fuse
Overload protection for 3 A to 10 A range: 11 A/1000 V; 10 × 38 mm 30 kA fast-acting fuse
Specification for 300 mA range: 440 mA continuous.
Specification for 10 A range: 10 A continuous. Add 0.3% to the specified accuracy when measuring signals >10 to 20 A for 30 seconds
maximum. After measuring currents >10 A, cool down the multimeter for twice the duration of the mea-sured time before proceeding with low
current measurements.
Overload protection: 1000 Vrms for short circuits with <0.3 A current.
Built-in buzzer beeps continuously when the voltage measured is less than 50 mV and beeps once for forward-biased di-ode or semiconductor
junctions measured between 0.3 V and 0.8 V (0.3 V ≤ reading ≤ 0.8 V).
Open voltage for diode: <+3.3 V DC
Open voltage for Auto diode: <+2.5 V DC and > -1.0 V DC
Overload protection: 1000 Vrms. For millivolt measurements, 1000 Vrms for short circuits with <0.3 A current.
Input impedance: 10 MΩ (nominal) in parallel with <100 pF.
Overload protection for 300 μA to 300 mA range: 0.44 A/1000 V; 10 × 35 mm 30 kA fast-acting fuse
Overload protection for 3 A to 10 A range: 11 A/1000 V; 10 × 38 mm 30 kA fast-acting fuse
Specification for 300 mA range: 440 mA continuous.
Specification for 10 A range: 10 A continuous. Add 0.3% to the specified accuracy when measuring signals >10 to 20 A for 30 seconds
maximum. After measuring currents >10 A, cool down the multimeter for twice the duration of the measured time before proceeding with low
current measurements.
[1]
[2]
Range
300 mV
enabled, applicable for
1000 V
all voltage ranges and
300 V
LPF (low pass fi lter)
30 V
3 V
resolution
3000 µA
300 mA
Range
300 µA
30 mA
10 A
3A
Resolution
0.0001 V
0.01 mV
0.001 V
0.01 V
0.1 V
Resolution
0.001 mA
0.0001 A
0.01 mA
0.01 µA
0.001 A
0.1 µA
45 Hz to
0.7 + 20
0.7 + 20
0.7 + 20
0.7 + 20
0.7 + 20
0.7 + 20
65 Hz
1.0 + 25 @ <200 Hz
5.0 + 25 @ <440 Hz
9
30 Hz to 1 kHz
45 Hz to 2 kHz
Accuracy
1.0 + 25
1.0 + 25
1.0 + 25
1.0 + 25
1.0 + 25
0.9 + 25
0.9 + 25
0.9 + 25
0.9 + 25
1.0 + 25
1.0 + 25
Accuracy
1 kHz to
2.0 + 25
2.0 + 25
2.0 + 25
2.0 + 25
5 kHz
-
-
Burden voltage/Shunt
5 kHz to
20 kHz
2.0 + 40
2.0 + 40
2.0 + 40
<0.04 V/ 100 Ω
<0.1 V/ 0.01 Ω
<0.3 V/ 0.01 Ω
<0.4 V/ 100 Ω
<0.08 V/ 1 Ω
<1.00 V/ 1 Ω
-
-
-