61-956 Ideal Industries, 61-956 Datasheet - Page 3

no-image

61-956

Manufacturer Part Number
61-956
Description
Circuit Tracer; Open/Closed; for circuits 0-600V AC/DC
Manufacturer
Ideal Industries
Type
Circuit Tracerr
Datasheet

Specifications of 61-956

Battery Life
40 hours open circuit testing / 25 hours short circuit tracing
Battery Type
Transmitter: (4) AA batteries × 1.5 V, Receiver: (3) AA batteries × 1.5 V
Current, Output
200 mA p-pMAX
Frequency, Operating
32 kilohertz
Fuse Type
1 A/1000 V, High-Energy, Fast-Acting (6 mm × 46 mm) — IDEAL # F-958
Includes
Transmitter, Receiver, Test Leads and Case
Indicator
On/Off, Line energized, Low battery
Sensing Range
15 Ft. Underground
Sensing Type
Magnetic
Signal Output
30 V Nominal
Voltage Range
0 to 600 VAC/VDC
Receiver:
1)
2)
3)
Battery Pack for Inductive Clamp:
Ensure the clamp is unplugged from the
battery pack.
1)
2)
3)
4)
5)
Fuse Replacement (TR-958 only)
Ensure that the test leads are removed from the
input jacks and the circuit under test.
1)
2)
3)
Remove the battery cap by loosening the screw.
Replace batteries with (3) new AA batteries.
Assemble cap and re-tighten the screw.
Remove cap by squeezing the ribbed tabs on
either side of the cap.
Remove the battery holder noting the
orientation to the strap mount on the case.
Replace batteries with (8) new C-cell batteries.
Re-install battery holder into the case noting
the orientation to the magnetic strap mount.
Snap cap back onto case.
Remove the (6) screws that are assembled
into the back of the transmitter.
Replace the fuse (#F-958).
Re-assemble the back cap and re-tighten the
(6) screws.
Page 21
Mount
Strap
Strap Mount
Ribbed
Ribbed Tabs
Tabs
Maintenance
Clean the case with a damp cloth and mild detergent. Do not use abrasives or solvents.
Service and Replacement Parts
This unit has no user-serviceable parts except for the fuse in the transmitter. For
replacement parts or to inquire about service, contact IDEAL Technical Support at
877-201-9005 or visit our website, www.testersandmeters.com.
Specifications:
Transmitter
Operating Frequency:
Current Output of Signal:
Voltage Output of Signal:
Operating Voltage:
Fuse:
Battery Power:
Battery life:
Indicators:
Receiver
Sensing:
Maximum range:
Signal response:
Battery Power:
Battery life:
32 kilohertz, fixed-amplitude, time-modulated signal
200mA p-p
30V nominal (2 watts)
0 – 600V AC/DC
1A/1000V, High-Energy, Fast-Acting (6mm x 46mm) –
IDEAL # F-958
1.5V x (4) AA batteries (NEDA 15A, IEC LR6)
40 hours open circuit testing / 25 hours short circuit tracing.
On/Off, Line energized, Low battery
Magnetic
15 feet underground.
Numeric display and Audible beep
1.5V x (3) AA batteries (NEDA 15A, IEC LR6)
20 hours
max
Page 22
into 50 ohms