XTOE005CCSS Eaton / Control Automation, XTOE005CCSS Datasheet
XTOE005CCSS
Specifications of XTOE005CCSS
Related parts for XTOE005CCSS
XTOE005CCSS Summary of contents
Page 1
Motor Protection and Monitoring C440/ XT Electronic Overload Relay 42 C440/XT Electronic Overload Relay Product Description 42 Eaton’s new electronic overload relay (EOL) is the most compact, high- 42 ...
Page 2
Benefits Flexibility Reliability and Improved Uptime Available with NEMA, ● C440 provides the users ● IEC and DP contactors with a peace of mind knowing that their Improves your return on ● assets are protected investment by reducing with the ...
Page 3
Motor Protection and Monitoring C440/ XT Electronic Overload Relay Catalog Number Selection 42 XT Electronic Overload Relay—IEC Designation line of IEC control 42 Type OE = Electronic overload relay ...
Page 4
Freedom Series NEMA Starters with C440 Electronic Overload Relays 005 Device Type A = Starter Standard N = NEMA Device Assembly Configuration OLR Type 1 = Non-reversing 9 = Starter w/C440 ...
Page 5
Motor Protection and Monitoring C440/ XT Electronic Overload Relay Product Selection 42 XT Electronic Overload Relays 42 XT Electronic Overload Relays for Direct Mount to XT Contactors for 42 Direct Mount For Use with XT Contactor ...
Page 6
... Catalog Number Catalog Number 750 kcmil XTOE005CCSS XTOE005CGSS (2) 250 kcmil 3/0 Cu/Al (2) 750 kcmil XTOE005CCSS XTOE005CGSS 3/0 Cu/Al (3) 750 kcmil XTOE005CCSS XTOE005CGSS 3/0 Cu/Al (4) 750 kcmil XTOE005CCSS XTOE005CGSS 1/0 Cu/Al Overload Relay with Ground Fault Catalog Number XTOE1P6CGSS XTOE005CGSS XTOE020CGSS XTOE045CGSS XTOE100GGSS ...
Page 7
Motor Protection and Monitoring C440/ XT Electronic Overload Relay C440 Electronic Overload Relays 42 C440 Electronic Overload Relays for Direct Mount C440 for 42 Freedom Series Contactors Direct Mount For Use with Freedom NEMA 42 Contactor ...
Page 8
Type AN19/59 Freedom Series Starters Type AN19/59 Freedom Series Starters with C440 Electronic Overload Relays Non-Reversing and Reversing NEMA Starter Continuous Service Limit NEMA Ampere Current Rating Size Rating (Amps ...
Page 9
Motor Protection and Monitoring C440/ XT Electronic Overload Relay Accessories 42 CT Kits 42 Accessories Description 42 Safety Cover Safety Cover 42 Clear Lexan cover that mounts on top of the FLA dial and DIP switches when closed. 42 ...
Page 10
The following information can be viewed using the communication option: Motor status—running, Percent thermal capacity ● ● stopped, tripped or Fault codes (only available ● resetting prior to reset) Individual rms phase ● Percent phase unbalance ● currents (A, B, ...
Page 11
Motor Protection and Monitoring C440/ XT Electronic Overload Relay Modbus Communication Module 42 The Modbus module combined with an expansion 42 module and a communication adapter provide Modbus 42 communication capability to the C440 electronic overload 42 relay. 42 ...
Page 12
Technical Data and Specifications Electronic Overload Relays up to 1500A Description Electrical Ratings Operating voltage (three-phase) and frequency FLA Range Use with Contactors XT IEC frames Freedom NEMA sizes Trip Class Motor Protection Thermal overload setting Feature Phase loss Phase ...
Page 13
Motor Protection and Monitoring C440/ XT Electronic Overload Relay Electronic Overload Relays up to 1500A, continued 42 Description 42 Auxiliary and Control Circuit Ratings 42 Conventional thermal continuous current Rated operational current—IEC AC-15 42 Make contact (1800 VA) 120V ...
Page 14
Electronic Overload Relays up to 1500A, continued Description Electrical/EMC Radiated emissions IEC 60947-4-1-Table 15 EN 55011 (CISPIR 11) Group 1, Class A, ISM Conducted emissions IEC 60947-4-1-Table 14 EN 55011 (CISPIR 11) Group 1; Class ISM ESD immunity IEC 60947-4-1 ...
Page 15
Motor Protection and Monitoring C440/ XT Electronic Overload Relay Communication Modules 42 Description Modbus 42 Electrical/EMC Radiated emissions 30–1000 mHz 42 IEC 60947-4-1—Table 15, EN 55011 (CISPIR 11) Group 1, Class A Conducted emissions 0.15–30 mHz 42 IEC 60947-4-1—Table ...
Page 16
Communication Modules, continued Description Modbus Operating Voltage Range—DC Input Modules OFF state 0–6 Vdc Transition region 6–18 Vdc ON state 18–30 Vdc C441_ 120 Vac Input Nominal input voltage 120 Vac Operating voltage 80–140 Vac Number of inputs 4 OFF-state ...
Page 17
Motor Protection and Monitoring C440/ XT Electronic Overload Relay Short Circuit Ratings (North America CSA, cUL) 42 Changes to UL 508A and NEC in recent years have brought a focus to control panel safety with regard to short-circuit current ...
Page 18
Dimensions Approximate Dimensions in Inches (mm C440/XT Electronic Overload Relays Dimensions Width Height A B NEMA Starter Size 00–2 1.80 (45.7) 4.60 (116.8) XT IEC Frame Size 1.80 (45.7) 4.30 (109.2) Standalone 0.35–45A 1.80 (45.7) ...
Page 19
Motor Protection and Monitoring C440/ XT Electronic Overload Relay Approximate Dimensions in Inches (mm C440/XT Electronic Overload Relays Dimensions ...
Page 20
Approximate Dimensions in Inches (mm) NEMA Starters Full Voltage Non-Reversing Starters E B Orientation C A Sizes 00 RESET C A Size 3 Dimensions NEMA Size A B 00, 0 1.97 (50.0) 6.60 (167. ...
Page 21
Motor Protection and Monitoring C440/ XT Electronic Overload Relay Approximate Dimensions in Inches (mm) 42 Full Voltage Reversing Starters Sizes 00 ...