MODEL 53/AL131EL Honeywell, MODEL 53/AL131EL Datasheet - Page 4

no-image

MODEL 53/AL131EL

Manufacturer Part Number
MODEL 53/AL131EL
Description
Transducer, Pressure, Load Cell, Model 53, Sensor, 20, 000 LBF
Manufacturer
Honeywell
Datasheet

Specifications of MODEL 53/AL131EL

Body Style
Cylindrical
Function
Pressure
Hysteresis
±0.3% Full Scale
Linearity
±0.5% Full Scale
Mounting Type
Flat Surface
Output
Voltage/Current
Output, Tolerance
2 mV/V (Nominal)
Primary Type
Pressure
Range, Measurement
20000 lbs.
Resolution
Infinite
Sensing Mode
Strain Gauge
Technology
Piezoelectric
Temperature, Operating, Range
–54 to +121 °C
Termination
Cable
Voltage, Excitation
10 VDC
Voltage, Supply
10 VDC
Voltage, Switching
2 mV/V
Weight
20000 Lbf
TYPICAL SYSTEM DIAGRAM
Sensing and Control
Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
NOTES
1.
2.
3.
4. TEDS available with integral cable units only.
5.
6.
Allowable maximum loads – maximum load to be applied without
damage.
Without damage - loading to this level will not cause excessive zero
shift or performance degradation. The user must consider fatigue
life for long term use and structural integrity. All structurally critical
applications (overhead loading, etc.) should always be designed
with safety redundant load paths.
Dimension “H” may increase with option 6i. Consult factory. Maxi-
mum temperature is 180 °F.
This unit calibrated to Imperial (non-Metric) units.
Signature calibration only available as inline module.
2
008638-1-EN IL50 GLO
May 2008
Copyright © 2008 Honeywell International Inc. All rights reserved.
Warranty. Honeywell warrants goods of its manufacture as
being free of defective materials and faulty workmanship.
Honeywell’s standard product warranty applies unless agreed
to otherwise by Honeywell in writing; please refer to your
order acknowledgement or consult your local sales office for
specific warranty details. If warranted goods are returned to
Honeywell during the period of coverage, Honeywell will repair
or replace, at its option, without charge those items it finds
defective. The foregoing is buyer’s sole remedy and is in lieu
of all warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special, or
indirect damages.
While we provide application assistance personally, through our
literature and the Honeywell web site, it is up to the customer to
determine the suitability of the product in the application.
Specifications may change without notice. The information we
supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.
For more information about Sensing and Control products, visit
www.honeywell.com/sensing or call +1-815-235-6847
Email inquiries to info.sc@honeywell.com
MISUSE OF DOCUMENTATION
Failure to comply with these instructions could result in
death or serious injury.
• The information presented in this catalogue is for
• Complete installation, operation and maintenance
PERSONAL INJURY
Failure to comply with these instructions could result in
death or serious injury.
• DO NOT USE these products as safety or emergency
reference only. DO NOT USE this document as product
installation information.
information is provided in the instructions supplied with
each product.
stop devices or in any other application where failure of
the product could result in personal injury.
WARNING
WARNING
Low Cost Load Cell

Related parts for MODEL 53/AL131EL